![Emerson Shafer ECAT Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/emerson/shafer-ecat/shafer-ecat_installation-operation-and-maintenance-manual_2400794023.webp)
Installation, Operation and Maintenance Manual
VA-DC-000-1952 Rev. 0
April 2021
20
Section 6: Maintenance
Maintenance
6.4
Recommended Annual Inspection
It is recommended the following components and features of the ECAT to be evaluated at least
once a year.
•
Check hydraulic fluid levels
•
Check the pressure gauges
•
Check bolts and fittings for tightness
•
Check for external oil leaks
•
Check the pneumatic fittings with a leak detection product such as Snoop liquid leak
detector from Swagelok or comparable.
•
Check handpump operation functions properly
•
If/When possible, perform a function test (See Section 4.6 for instructions on how to
perform a function test)
•
Check accumulator and thermal volume controller function
•
Check the breather on the hydraulic reservoir
•
Check the return filter, if included
Qualified service personnel are available upon request. Please feel free to contact:
EMERSON AUTOMATION SOLUTIONS
ACTUATION TECHNOLOGIES
Address:
2500 PARK AVENUE WEST
ONTARIO, OH 44906
Telephone:
(419) 529-4311
Fax:
(419) 529-3688