background image

Installation Instructions 

SH/Install/2016-09 Rev. 1

  

September 2016

10

Section 3: Step by Step Installation on Valve

Step by Step Installation on Valve

Figure 12 

Mounting the Actuator to the Adapter

Adapter

Angle Bearing

4. 

Remove the 3/8” socket head cap screws and banana washers. Lift the actuator 
off the adapter, see illustration at the top. Now turn the bracket to line up the bolt 
holes and install the 3/8” hex head cap screws, lockwashers and nuts.  
Loosen the adjusting screws to allow them to pass angle bearing and lower the 
actuator back onto the adapter. Use care aligning the spline in the adapter with 
the one on the actuator.  
Replace the 3/8” socket head cap screws and banana washers and tighten. Tighten 
the hex head cap screws and nuts. Tighten the adjusting screws against the angle 
bearing.

Содержание SH Series

Страница 1: ...Installation Instructions SH Install 2016 09 Rev 1 September 2016 Shafer SH Series ...

Страница 2: ......

Страница 3: ... SH Install 2016 09 Rev 1 Table of Contents September 2016 Table of Contents Section 1 SH Series Installed on Valve Section 2 Adaption Parts Section 3 Step by Step Installation on Valve Appendix A List of Figures Table of Contents ...

Страница 4: ...nstall 2016 09 Rev 1 September 2016 1 Section 1 SH Series Installed on Valve SH Series Installed on Valve Section 1 SH Series Installed on Valve Figure 1 SH Series Installed on Valve Actuator Controls Coupling Valve Mounting Bracket ...

Страница 5: ...ion Instructions SH Install 2016 09 Rev 1 September 2016 2 Section 2 Adaption Parts Adaption Parts Section 2 Adaption Parts Figure 2 Adaption Parts Adapter Angle Bearing Pin Bearing Seal Flange Coupling Bracket ...

Страница 6: ...Installation Instructions SH Install 2016 09 Rev 1 September 2016 3 Section 2 Adaption Parts Adaption Parts Figure 3 Flange Top Part Overview Flange Top Machined to fit actuator Figure 4 Flange Bottom ...

Страница 7: ...ctions SH Install 2016 09 Rev 1 September 2016 4 Section 2 Adaption Parts 4 Adaption Parts Part Overview Flange Bottom Machined to bracket Figure 5 Adapter Part Overview Adapter Machined to fit coupling Figure 6 Coupling ...

Страница 8: ...ptember 2016 5 Section 2 Adaption Parts Adaption Parts Part Overview Coupling Top machined to fit bottom of adapter bottom machined to fit valve stem Figure 7 Bracket Part Overview Bracket Top machined to fit bottom of flange bottom machined to fit valve ...

Страница 9: ...ns SH Install 2016 09 Rev 1 September 2016 6 Section 3 Step by Step Installation on Valve Step by Step Installation on Valve Section 3 Step by Step Installation on Valve Figure 8 Installation of an SH Series Actuator on Valve ...

Страница 10: ...Section 3 Step by Step Installation on Valve Step by Step Installation on Valve Figure 9 Mounting the Coupling on the Valve Stem Simulated valve stem and mounting position 1 Determine orientation and mount the coupling on the valve stem NOTE Valve shown in open position ...

Страница 11: ...uator to the Coupling Handle is threaded so it can be removed for ease of assembly 2 With the actuator assembly supported by a proper means work the bracket down over the handle until the bracket rests on the valve NOTE Handle may be removed for clearance Replace and tighten after the bracket is seated Actuator shown without controls for clarity It will ship fully assembled ...

Страница 12: ...ng Screw one on each side not shown 3 8 Diameter Hex Head Screws 3 Fasten the bracket to the valve using the 3 8 diameter hex head cap screws lock washers and hex nuts supplied It may be necessary to loosen the socket head cap screws retaining the banana washers and turn the bracket using the adjusting screws to line up the bolt holes If unable to achieve alignment the adapter will have to be turn...

Страница 13: ...ff the adapter see illustration at the top Now turn the bracket to line up the bolt holes and install the 3 8 hex head cap screws lockwashers and nuts Loosen the adjusting screws to allow them to pass angle bearing and lower the actuator back onto the adapter Use care aligning the spline in the adapter with the one on the actuator Replace the 3 8 socket head cap screws and banana washers and tight...

Страница 14: ...9 Rev 1 September 2016 11 Section 3 Step by Step Installation on Valve Step by Step Installation on Valve Table 1 Adjustment Available Size Angle Adjustment With Screws With Adapter SH 4 5 7 5o 5o tooth SH 9 0 7 5o 5o tooth SH 18 0 7 5o 5o tooth ...

Страница 15: ...rts 2 Figure 3 Flange Top 3 Figure 4 Flange Bottom 3 Figure 5 Adapter 4 Figure 6 Coupling 4 Figure 7 Bracket 5 Figure 8 Installation of an SH Series Actuator on Valve 6 Figure 9 Mounting the Coupling on the Valve Stem 7 Figure 10 Mounting the Actuator to the Coupling 8 Figure 11 Fastening the Bracket using Head Cap Screws 9 Figure 12 Mounting the Actuator to the Adapter 10 ...

Страница 16: ......

Страница 17: ...O Box 10305 Jubail 31961 Saudi Arabia T 966 3 340 8650 F 966 3 340 8790 24 Angus Crescent Longmeadow Business Estate East P O Box 6908 Greenstone 1616 Modderfontein Extension 5 South Africa T 27 11 451 3700 F 27 11 451 3800 EUROPE Berenyi u 72 100 Videoton Industry Park Building 230 Székesfehérvár 8000 Hungary T 36 22 53 0950 F 36 22 54 3700 www emerson com shafer 2017 Emerson All rights reserved ...

Отзывы: