7
Product Certifications
Rev: 2.0
European Directive Information
A copy of the EU Declaration of Conformity can be found at the end of the
Quick Start Guide. The most recent revision of the EU Declaration of
Conformity can be found at
.
Ordinary Location Certification from CSA
The product has been examined and tested to determine that the design
meets the basic electrical, mechanical, and fire protection requirements by
CSA, a nationally recognized test laboratory (NRTL) as accredited by the
Federal Occupational Safety and Health Administration (OSHA).
Installing in North America
The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC)
permit the use of Division marked equipment in Zones and Zone marked
equipment in Divisions.The markings must be suitable for the area
classification, gas, and temperature class. This information is clearly defined in
the respective codes.
USA
I5
U.S.A. Intrinsically Safe (IS)
Certificate:
[CSA] 70047656
Standards:
FM 3600 – 2011, FM 3610 – 2010, UL Standard 50 – Eleventh
Edition, UL 61010-1 – 3rd Edition, ANSI/ISA-60079-0
(12.00.01) – 2013, ANSI/ISA-60079-11 (12.02.01) – 2013,
ANSI/IEC 60529 – 2004
Markings:
IS CL I, DIV 1, GP A, B, C, D T4; Class 1, Zone 0, AEx ia IIC T4 Ga;
T4 (–40 °C ≤ T
a
≤ +70 °C) when installed per Rosemount
drawing 00G45-1020; Type 4X; IP66/67;
Special Conditions for Safe Use(X):
1. Do not replace battery when explosive atmosphere is present.
2. Use only 00G45-9000-0001 batteries.
3. The surface resistivity of the housing is greater than 1G
. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with
solvents or a dry cloth.
4. Substitution of components may impair intrinsic safety.
February 2019
Quick Start Guide
Quick Start Guide
13