Quick Installation Guide
00825-0100-4662, Rev CC
December 2012
Rosemount 8732
2
© 2013 Rosemount Inc. All rights reserved. All marks property of owner.
IMPORTANT NOTICE
This document provides basic installation guidelines for the Rosemount
®
8732. It does
not provide instructions for detailed configuration, diagnostics, maintenance, service,
troubleshooting, explosion-proof, flame-proof, or intrinsically safe (I.S.) installations.
Refer to the Rosemount 8732 reference manual (document number 00809-0100-4662)
for more instructions. The manual and this QIG are also available electronically on
www.rosemount.com.
WARNING
Failure to follow these installation guidelines could result in death or serious
injury:
Installation and servicing instructions are for use by qualified personnel only. Do not
perform any servicing other than that contained in the operating instructions, unless
qualified. Verify that the operating environment of the sensor and transmitter is consistent
with the appropriate FM, CSA, ATEX, or IECEx approval.
Do not connect a Rosemount 8732 to a non-Rosemount sensor that is located in an
explosive atmosphere.
WARNING
The sensor liner is vulnerable to handling damage. Never place anything through the
sensor for the purpose of lifting or gaining leverage. Liner damage can render the sensor
useless.
To avoid possible damage to the sensor liner ends, do not use metallic or spiral-wound
gaskets. If frequent removal is anticipated, take precautions to protect the liner ends.
Short spool pieces attached to the sensor ends are often used for protection.
Correct flange bolt tightening is crucial for proper sensor operation and life. All bolts must
be tightened in the proper sequence to the specified torque limits. Failure to observe
these instructions could result in severe damage to the sensor lining and possible sensor
replacement.
WARNING
Rosemount 8705 Magnetic Flowtube units ordered with non-standard paint options may
be subject to electrostatic discharge.
To avoid electrostatic charge build-up, do not rub the meter body with a dry cloth or clean
with solvents.
Emerson Process Management
Rosemount Flow
7070 Winchester Circle,
Boulder, CO 80301
Tel (USA) 800 522 6277
Tel (International) +1 (303) 527 5200
Fax +1 (303) 530 8459
Emerson Process
Management Flow
Neonstraat 1
6718 WX Ede
The Netherlands
T +31 (0)318 495555
F +31(0) 318 495556
Emerson Process
Management Asia Pacific
Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947/65 6777 0743
Emerson FZE
P.O. Box 17033
Jebel Ali Free Zone
Dubai UAE
Tel +971 4 811 8100
Fax +971 4 886 5465
4662RevCCQIG.fm Page 2 Thursday, January 10, 2013 5:11 PM