Ambient Temperature Effect
Transmitters can be installed in locations where the ambient temperature is
between –40 and 85 °C (–40 and 185 °F). In order to maintain excellent
accuracy performance, each transmitter is individually characterized over this
ambient temperature range at the factory.
Temperature Effects Example
When using a Pt 100 (a = 0.00385) sensor input with a 0–100 °C span at
30 °C ambient temperature:
• Digital Temperature Effects: 0.003 °C x (30 - 20) = 0.03 °C
• D/A Effects: [0.001% of 100] x (30 - 20) = 0.01 °C
• Worst Case Error: D D/A + Digital Temperature E D/A
Effects = 0.15 °C + 0.03 °C + 0.03 °C + 0.01 °C = 0.22 °C
• Total Probable Error:
Table A-3. Ambient Temperature Effect
Sensor Options
Temperature Effects per 1.0 °C (1.8 °F) Change
in Ambient Temperature
(1)
(1) Change in ambient is with reference to the calibration temperature of the transmitter 68 °F (20 °C) from factory.
Range
D/A Effect
2-, 3-, 4-wire RTDs
Pt 100 ((
α
= 0.00385)
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Pt 100 (
α
= 0.003916)
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Pt 200
0.004 °C (0.0072 °F)
Entire Sensor Input Range
0.001% of span
Pt 500
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Pt 1000
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Ni 120
0.003 °C (0.0054 °F)
Entire Sensor Input Range
0.001% of span
Cu 10
0.03 °C (0.054 °F)
Entire Sensor Input Range
0.001% of span
Thermocouples
Type B
0.014 °C
R
≥
1000°C
0.001% of span
0.032 °C – (0.0025% of (R – 300))
300 °C
≤
R < 1000 °C
0.001% of span
0.054 °C – (0.011% of (R – 100))
100 °C
≤
R< 300 °C
0.001% of span
Type E
0.005 °C +(0.00043% of R)
All
0.001% of span
Type J
0.0054 °C +(0.0029%of R)
R
≥
0 °C
0.001% of span
0.0054 °C + (0.0025% of absolute value R)
R < 0 °C
0.001% of span
Type K
0.0061 °C +(0.00054% of R)
R
≥
0 °C
0.001% of span
0.0061 °C + (0.0025% of absolute value R)
R < 0 °C
0.001% of span
Type N
0.0068 °C +(0.00036% of R)
All
0.001% of span
Type R, S, W5Re/W26Re
0.016 °C
R
≥
200°C
0.001% of span
0.023 °C – (0.0036% of R)
R < 200 °C
0.001% of span
Type T
0.0064 °C
R
≥
0 °C
0.001% of span
0.0064 °C +(0.0043% of absolute value R)
R < 0 °C
0.001% of span
DIN Type L
0.0054 °C + (0.00029% of R)
R
≥
0 °C
0.001% of span
0.0054 °C +(0.0025% of absolute value R)
R < 0 °C
0.001% of span
DIN Type U
0.0064 °C
R
≥
0 °C
0.001% of span
0.0064 °C +(0.0043% of absolute value R)
R < 0 °C
0.001% of span
Millivolt Input
0.0005 mV
Entire Sensor Input Range
0.001% of span
2-, 3-, 4-wire Ohm
0.0084
Ω
Entire Sensor Input Range
0.001% of span
0.15
2
0.03
2
0.03
2
0.01
2
+
+
+
0.16
°
C
=
Содержание Rosemount 644h
Страница 2: ......
Страница 4: ......
Страница 26: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 2 16 ...
Страница 50: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 4 10 ...
Страница 64: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R A 14 ...
Страница 77: ......