Reference Manual
00809-0100-4728, Rev HA
December 2002
Models 644H and 644R
4-8
Exceed precision
Indicates that the precision for the current arithmetic variable exceeds the device- specified
description edit format.
Ignore next 50 occurrences of status?
Asked after displaying device status. Softkey answer determines whether next 50 occurrences
of device status will be ignored or displayed.
Illegal character
An invalid character for the variable type was entered.
Illegal date
The day portion of the date is invalid.
Illegal month
The month portion of the date is invalid.
Illegal year
The year portion of the date is invalid.
Incomplete exponent
The exponent of a scientific notation floating point variable is incomplete.
Incomplete field
The value entered is not complete for the variable type.
Looking for a device
Polling for multidropped devices at addresses 1–15.
Mark as read only variable on hotkey
menu?
Asks whether the user should be allowed to edit the variable from the hotkey menu if the item
being added to the hotkey menu is a variable.
No device configuration in configuration
memory
There is no configuration saved in memory available to re-configure off-line or transfer to
a device.
No Device Found
Poll of address zero fails to find a device, or poll of all addresses fails to find a device if
auto-poll is enabled.
No hotkey menu available for this device.
There is no menu named “hotkey” defined in the device description for this device.
No offline devices available.
There are no device descriptions available to be used to configure a device offline.
No simulation devices available.
There are no device descriptions available to simulate a device.
No UPLOAD_VARIABLES in ddl for this
device
There is no menu named “upload_variables” defined in the device description for this device.
This menu is required for offline configuration.
No Valid Items
The selected menu or edit display contains no valid items.
OFF KEY DISABLED
Appears when the user attempts to turn the Model 275 HART Communicator off before sending
modified data or before completing a method.
Online device disconnected with unsent
data. RETRY or OK to lose data.
There is unsent data for a previously connected device. Press RETRY to send data, or press
OK to disconnect and lose unsent data.
Out of memory for hotkey configuration.
Delete unnecessary items.
There is no more memory available to store additional hotkey items. Unnecessary items should
be deleted to make space available.
Overwrite existing configuration memory
Requests permission to overwrite existing configuration either by a device-to-memory transfer
or by an offline configuration. User answers using the softkeys.
Press OK.
Press the OK softkey. This message usually appears after an error message from the
application or as a result of HART communications.
Restore device value?
The edited value that was sent to a device was not properly implemented. Restoring the device
value returns the variable to its original value.
Save data from device to configuration
memory
Prompts user to press SAVE softkey to initiate a device-to-memory transfer.
Saving data to configuration memory.
Data is being transferred from a device to configuration memory.
Sending data to device.
Data is being transferred from configuration memory to a device.
There are write only variables which have
not been edited. Please edit them.
There are write-only variables which have not been set by the user. These variables should be
set or invalid values may be sent to the device.
There is unsent data. Send it before
shutting off?
Press YES to send unsent data and turn the Model 275 HART Communicator off. Press NO to
turn the Model 275 HART Communicator off and lose the unsent data.
Too few data bytes received
Command returns fewer data bytes than expected as determined by the device description.
Transmitter Fault
Device returns a command response indicating a fault with the connected device.
Units for <variable label> has changed. Unit
must be sent before editing, or invalid data
will be sent.
The engineering units for this variable have been edited. Send engineering units to the device
before editing this variable.
Unsent data to online device. SEND or
LOSE data
There is unsent data for a previously connected device which must be sent or thrown away
before connecting to another device.
Use up/down arrows to change contrast.
Press DONE when done.
Gives direction to change the contrast of the Model 275 HART Communicator display.
Message
Description
Содержание Rosemount 644h
Страница 2: ......
Страница 4: ......
Страница 26: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 2 16 ...
Страница 50: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R 4 10 ...
Страница 64: ...Reference Manual 00809 0100 4728 Rev HA December 2002 Models 644H and 644R A 14 ...
Страница 77: ......