Reference Manual
00809-0100-4728, Rev MB
Configuration
July 2016
Configuration
Using a Field Communicator
The Configure Sensors method will guide you through the configuration of all necessary settings
associated with configuring a sensor including:
For a full list of Sensor Types available with the Rosemount 644 and their associated levels of accuracy,
see
Table A-2 on page 110
.
Using AMS Device Manager
Right click on the device and select
Configure
.
1. In the left navigation pane choose
Manual Setup
and choose the
Sensor 1
or
Sensor 2
tab
depending on the need.
2. Individually select the Sensor Type, Connection, Units and other sensor related information as desired
from the drop down menus on the screen.
3. Click
Apply
when complete.
Using Local Operator Interface
Reference the below image for guidance on where to find Sensor Configuration in the LOI menu.
Figure 2-6. Configuring Sensors with LOI
* Available only if option code (S) is ordered.
Contact a Emerson Process Management representative for information on the temperature sensors,
thermowells, and accessory mounting hardware that is available through Emerson Process
Management.
2-wire RTD offset
The 2-wire Offset feature allows the measured lead wire resistance to be input and corrected for, which
results in the transmitter adjusting its temperature measurement for the error caused by this added
resistance. Because of a lack of lead wire compensation within the RTD, temperature measurements
made with a 2-wire RTD are often inaccurate.
This feature can be configured as a subset of the
Sensor Configuration
process in the Field
Communicator, AMS Device Manager, and the Local Operator Interface.
To utilize this feature properly perform the following steps:
From the
HOME
screen, enter the Fast Key sequence
Device Dashboard Fast Keys
2, 1, 1
VIEW SENSOR
VIEW SENSOR
SENSOR CONFIG
SENSOR CONFIG
BACK TO MENU
EXIT MENU
VIEW S1 CONFIG
VIEW S2 CONFIG*
BACK TO MENU
EXIT MENU
VIEW CONFIG
SENSOR CONFIG
SENSOR CONFIG
UNITS
RERANGE
LOOP TEST
DISPLAY
EXTENDED MENU
EXIT MENU
SENSOR 1 CONFIG
SENSOR 2 CONFIG*
BACK TO MENU
EXIT MENU
Содержание Rosemount 644 HART
Страница 2: ......
Страница 16: ...6 Reference Manual 00809 0100 4728 Rev MB Introduction July 2016 Introduction ...
Страница 80: ...70 Reference Manual 00809 0100 4728 Rev MB Operation and Maintenance July 2016 Operation and Maintenance ...
Страница 86: ...76 Reference Manual 00809 0100 4728 Rev MB Troubleshooting July 2016 Troubleshooting ...
Страница 120: ...Product Certifications July 2016 Reference Manual 00809 0100 4728 Rev MB 110 Product Certifications Sheet 2 of 2 ...
Страница 122: ...Product Certifications July 2016 Reference Manual 00809 0100 4728 Rev MB 112 Product Certifications ...
Страница 138: ...128 Reference Manual 00809 0100 4728 Rev MB Index July 2016 Index ...
Страница 139: ......