Reference Manual
00809-0100-4811, Rev CA
February 2006
Rosemount 3300 Series
3-18
Anchoring
In turbulent tanks it may be necessary to fix the probe. Depending on the
probe type different methods can be used to guide the probe to the tank
bottom. This may be needed in order to prevent the probe from hitting the
tank wall or other objects in the tank, as well as preventing a probe from
breaking.
Flexible Twin/Single Lead
probe
with weight and ring.
A ring (customer supplied) can be
attached to the weight in a threaded
(M8x14) hole at the end of the
weight. Attach the ring to a suitable
anchoring point.
Flexible Twin/Single Lead
probe
with weight and magnet.
A magnet (customer supplied) can
be fastened in a threaded (M8x14)
hole at the end of the weight. The
probe can then be guided by placing
a suitable metal plate beneath the
magnet.
Coaxial
probe fixed to the tank wall.
The coaxial probe can be guided to
the tank wall by fixtures fastened to
the tank wall. Fixtures are customer
supplied. Make sure the probe can
move freely due to thermal
expansion without getting stuck in
the fixture.
Weight with
internal threads
M8x14
Ring
PROB
EA
NCH
O
R
RING
FL
EX
IBL
E
TW
IN
Magnet
P
R
OBE
A
NCHOR MA
GNET FL
E
X
IB
LE
TWIN
1.1 inch/28 mm
P
R
O
BE SU
PPO
R
T
C
O
AX
Содержание Rosemount 3300 Series
Страница 2: ......
Страница 4: ......
Страница 8: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series TOC 4 ...
Страница 12: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 1 4 ...
Страница 24: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 2 12 ...
Страница 104: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 6 24 ...
Страница 128: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series A 24 ...
Страница 145: ......