Reference Manual
00809-0100-4811, Rev CA
February 2006
Rosemount 3300 Series
3-16
Rigid Twin Lead
The spacers are put closer together at the probe end. The maximum amount
that can be cut away is related to the ordering length
L
.
To cut a Rigid Twin Lead probe do the following:
1. Cut the rods to the desired length:
•
You may cut up to 19.7 inch (500
mm) from the probe end for probe
length
L
above 46.5 in. (1180 mm).
•
For probe length
20.5 to 46.5 in. (520 to 1180 mm)
the minimium length is
20.5 in. (520 mm).
•
For probe length 15.7 to 20.5 in.
(400 to 520 mm) the minimium
length is 15.7 in. (400 mm).
2. Update the transmitter configuration
to the new probe length, see “Probe
Length“ on page 4-9.
Max. shortening length:
19.7 in. / 500 mm
R
IGI
DT
WI
N_SHO
R
T_
BA.
EP
S
L>46.5 in. (1180 mm)
L
RIGIDT
WIN_
SHORT_BA
_2.EP
S
20.5 < L<46.5 inch
Minimum probe length
20.5 inches / 520 mm
L
(520 mm< L <1180 mm)
RIGIDT
WIN
_
SHORT_B
A
_3.EP
S
Minimum probe length
15.7 inches / 400 mm
L
15.7< L<20.5 inch
(400< L<520 mm)
Содержание Rosemount 3300 Series
Страница 2: ......
Страница 4: ......
Страница 8: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series TOC 4 ...
Страница 12: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 1 4 ...
Страница 24: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 2 12 ...
Страница 104: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 6 24 ...
Страница 128: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series A 24 ...
Страница 145: ......