5
Troubleshooting
This table includes the steps needed to correct errors with the temperature transmitter.
1. Connect the temperature transmitter to a PC.
2. Read the value for the parameter
Fnr
.
3. Take corrective measures as instructed by this table:
Fnr
Type of fault
Corrective measures
0
No fault, no anomaly occurred.
None
20
Internal malfunction in the transmitter
electronics.
Replace the temperature transmitter.
21
Sensor backup is active, possibly because a
sensor element failed.
1. Replace the temperature transmitter.
2. Continue measurement with only one
sensor element while waiting for
replacement transmitter:
•
In two-wire operation, set
drEd
to
ON so the remaining temperature
sensor element can communicate
the measured temperature value
using the analog signal. In this
case, the analog output provides
diagnostics in case of a failure.
•
In three-wire operation, the
temperature transmitter can signal
all diagnostic cases using the
switching output except those
used for drift monitoring
(diagnostic cases 1, 3, 7).
30
Wiring fault
Check the wiring.
42
The temperature is outside the allowable
temperature range. The analog signal is
21.5 mA (FOU2 = On) or 3.5 mA (FOU2 =
OFF)
1. Check measuring range.
2. Adjust
ASP
and
AEP
values to
accommodate the operating
conditions or correct the process
temperature.
71
Detected sensor drift exceeds warning level
drW
At the first detected drift.
1. Check if the parameter
drW
is
programmed correctly.
2. Prepare replacement of the unit.
72
Drift exceeds alarm threshold
drA
. The
temperature measurement might be less
accurate.
1. Check that the parameter
drA
is
programmed correctly.
2. Replace the temperature transmitter.
Quick Start Guide
Troubleshooting
00825-0100-4329
January 2019
Quick Start Guide
21
Содержание Rosemount 327T
Страница 1: ...Quick Start Guide 00825 0100 4329 Rev 01 January 2019 Rosemount 327T Temperature Transmitter ...
Страница 2: ...2 ...
Страница 4: ...Contents Quick Start Guide January 2019 00825 0100 4329 4 Quick Start Guide ...
Страница 12: ...Introduction Quick Start Guide January 2019 00825 0100 4329 12 Quick Start Guide ...
Страница 16: ...Installation Quick Start Guide January 2019 00825 0100 4329 16 Quick Start Guide ...
Страница 20: ...Setting range for drW and drA Quick Start Guide January 2019 00825 0100 4329 20 Quick Start Guide ...
Страница 24: ...Product certifications Quick Start Guide January 2019 00825 0100 4329 24 Quick Start Guide ...