European Certifications
I1
ATEX Intrinsic Safety
Certificate No.: BAS01ATEX1303X
II 1 G
EEx ia IIC T4 (T
a
= -60 °C to 70 °C)
-HART/Remote Display/Quick Connect/HART Diagnostics
1180
Special Conditions for Safe Use (X)
1. The apparatus, excluding the Types 3051 S-T and 3051 S-C
(In-line and Coplanar SuperModule Platforms respectively), is
not capable of withstanding the 500V test as defined in Clause
6.4.12 of EN 50020. This must be considered during
installation.
2. The terminal pins of the Types 3051 S-T and 3051 S-C must
be protected to IP20 minimum.
N1
ATEX Type n
Certificate No.: BAS01ATEX3304X
II 3 G
EEx nL IIC T4 (T
a
= -40 °C TO 70 °C)
Ui = 45 Vdc max
IP66
Table 2. Input Parameters
Loop / Power
Groups
U
i
= 30V
All
I
i
= 300 mA
All
P
i
= 1.0W
All
C
i
= 30nF
SuperModule
™
/Quick Connect
C
i
= 11.4nF
With PlantWeb or Junction Box Housing
C
i
= 0
Remote Display
L
i
= 0
All Except Remote Display
L
i
= 60 µH
Remote Display
4801_QIG_RevHA.fm Page 26 Tuesday, February 26, 2008 12:17 PM
Содержание Rosemount 3051S Series
Страница 32: ...Quick Installation Guide 00825 0100 4801 Rev HA February 2008 Rosemount 3051S 32 DOC ...
Страница 33: ...Quick Installation Guide 00825 0100 4801 Rev HA February 2008 Rosemount 3051S 33 ...
Страница 34: ...Quick Installation Guide 00825 0100 4801 Rev HA February 2008 Rosemount 3051S 34 ...
Страница 35: ...Quick Installation Guide 00825 0100 4801 Rev HA February 2008 Rosemount 3051S 35 ...
Страница 36: ...Quick Installation Guide 00825 0100 4801 Rev HA February 2008 Rosemount 3051S 36 NOTES ...