45
Specifications and Reference Data
Specifications and Reference Data
October 2016
Reference Manual
00809-0100-4808, Rev DA
A.3.10 Maximum working pressure
(1)(2)
Rosemount 3051ND
Static pressure limit
Rosemount 3051NG and Rosemount 3051NA
Upper range limit
A.3.11 Static pressure limits
Operates within specifications between static line pressures stated
below
Rosemount 3051ND only
A.3.12 Overpressure limits
Transmitters withstand the following overpressure
without damage:
Rosemount 3051ND/NG
Rosemount 3051NA
A.3.13 Burst pressure
Minimum burst pressure is 10,000 psig (69 MPa).
A.4 Physical specifications
A.4.1 Materials of construction
Isolating diaphragms
316L SST
Drain/vent valves
316 SST
Process flanges
CF-8M (cast version of 316 SST)
Process O-rings
Glass-filled TFE, Ethylene propylene (optional)
Fill fluid
Silicone oil
Flange bolts
Plated carbon steel, per ASTM A449, Type 1 or SAE J492 Grade 5
(austenitic 316 SST per ASTM F593 for the Rosemount 3051N
Range Code 0)
Electronics housing
Low-copper aluminum with polyurethane paint, or CF-8M (cast
version of 316 SST)
Non-wetted O-rings
Ethylene propylene elastomer
Sensor module housing
CF-3M (cast version of 316L SST per ASTM-A743)
Mounting bracket
AISI 1010 steel or JIS G3131 SPHC P/O Steel with polyurethane
paint (Option Code B2), 304 SST per ASTM 554 (Option Code B4),
316L SST (Option Code BS), or SST (Option Code PM)
Mounting bolts (bracket-to-transmitter)
Carbon steel, per ASTM A449, Type 1 or SAE J429 Grade 5 (Option
Code B2, BS, PM), 316 SST per ASTM F-593 (Option Code B4)
Process connections
1
/
4
-18 NPT
Electrical connections
1
/
2
-14 NPT conduit with screw terminals
1.
EPR process O-ring (Code B) is limited to 2000 psi maximum working pressure.
2.
See
Table A-2
for specified Seismic Maximum Working Pressure.
Range code Static pressure limits
0
0.5 psia to 750 psig (3,4 kPa abs to 5,2 MPa)
1
0.5 psia to 2000 psig (3,4 kPa abs to 13,8 MPa)
2 – 5
(1)
1.
EPR process O-ring (Code B) is limited to 2000 psi maximum working
pressure.
0.5 psia to 3626 psig (3,4 kPa abs to 25 MPa)
Range code Overpressure limits
0
750 psig (5,2 MPa)
1
2000 psig (13,8 MPa)
2 – 5
(1)
1.
EPR process O-ring (Code B) is limited to 2000 psi maximum working
pressure.
3626 psig (25 MPa)
Range code Overpressure limits
1
120 psia (827 kPa)
2
300 psia (2 070 kPa)
3
1600 psia (11 030 kPa)
4
(1)
1.
EPR process O-ring (Code B) is limited to 2000 psi maximum working
pressure.
6000 psia (41 370 kPa)
Содержание Rosemount 3051N
Страница 2: ...This page intentionally left blank ...
Страница 66: ...Options October 2016 Reference Manual 00809 0100 4808 Rev DA 58 Options This page intentionally left blank ...
Страница 82: ...Glossary October 2016 Reference Manual 00809 0100 4808 Rev DA 74 Glossary This page intentionally left blank ...