32
Reference Manual
00809-0100-2460, Rev DE
October 2018
3.5.7
Wiring
The terminal compartment has a terminal board for connecting communication buses to host systems
and field devices. The terminal compartment also has a connection for power supply. Three Ethernet
connections are available for LAN communication.
1. Ensure that the power supply is switched off.
Note!
If any uncertainty exists whether power supply is
off or not, make sure that loose cable ends don’t run through the cover on the power board.
2. Loosen the two captive screws and open the lid (see
Note!
The lid can be removed from
the housing for easier access when open more than 25°. Remove the locking ring and carefully slide
the lid upwards 21 mm or more. Be careful not to drop it on the floor.
3. Run wires through a cable gland. Install wiring with a drip loop in such a way that the lower part of the
loop is under the cable entry.
4. Connect wires to the terminal block.
See
“Terminal board and ports” on page 33
for information on terminal block bus connections.
See
for examples on how to connect the Rosemount 2460 to various
host systems and field devices.
For wiring of
redundant
system hubs see
5. Use the enclosed metal plugs to seal any unused cable entries.
6. Tighten the conduits/cable glands.
7. Make sure that the Lock ring on the cover to the communication board compartment is folded so that
it does not prevent the lid from being properly closed. Attach the lid in case it was removed from the
housing and close it. Torque the two screws to 4Nm (35 in.-lb). Ensure that it is fully engaged to
prevent water from entering the terminal compartment.
Note
Ensure that gasket and seats are in good condition prior to mounting the cover in order to maintain the
specified level of ingress protection. The same requirements apply for cable inlets and outlets (or plugs).
Cables must be properly attached to the cable glands.
Figure 3-4. Rosemount 2460 Front View
Port 1
ETH
1
Port 2
Port 3
Port 4
Port 5
Port 6
Port 7a
Port 7b
Port 8b
Port 8a
ETH
3
ETH
2
WRITE PROT
ON/OFF
SD CARD
SERVICE
2460-
TAG:
S/N:
MFG (yymmdd):
DEVICE ID:
MAINS: 100-250VAC 50/60Hz, 24-48VDC 20W
MADE IN GOTHENBURG SWEDEN
Captive screws x 2
Lid
Power Board
Lock ring
Lock ring
Cover for communication
board compartment
Содержание Rosemount 2460
Страница 2: ......
Страница 4: ...ii Reference Manual 00809 0100 2460 Rev DE Title Page October 2018 Title Page ...
Страница 12: ...x Reference Manual 00809 0100 2460 Rev DE Contents October 2018 Contents ...
Страница 18: ...6 Reference Manual 00809 0100 2460 Rev DE Introduction October 2018 Introduction ...
Страница 60: ...48 Reference Manual 00809 0100 2460 Rev DE Installation October 2018 Installation ...
Страница 100: ...88 Reference Manual 00809 0100 2460 Rev DE Configuration October 2018 Configuration ...
Страница 182: ...170 Product Certifications Product Certifications October 2018 Reference Manual 00809 0100 2460 Rev DE ...
Страница 214: ...202 Modbus Standard Question Modbus Standard Question October 2018 Reference Manual 00809 0100 2460 Rev DE ...
Страница 230: ...218 Varec Device Configuration Varec Device Configuration October 2018 Reference Manual 00809 0100 2460 Rev DE ...
Страница 238: ...226 Reference Manual 00809 0100 2460 Rev DE Index October 2018 Index ...
Страница 239: ......