B.7 Safety Integrity Level (SIL)
certification
The Rosemount 2130 is SIL2-certified. It has been independently
certified to IEC 61508 as required by IEC 61511. Certification was
conducted by Exida.
A detailed Failure Modes, Effects and Diagnostics Analysis (FMEDA)
report for the Rosemount 2130 is available from Emerson. This
report details all failure rates and failure modes as well as expected
lifetime. The FMEDA report is available from the Document and
Drawings tab on the
. There are SIL
documents including the FMEDA report, certificate, and Functional
Safety Manual.
B.8 Canadian Registration Number
Certificate Number CRN 0F04227.2C
The requirements of CRN are met when a Rosemount 2130
CSA-approved vibrating fork level switch (with Product
Certification codes G6, E6, or I6) is configured with stainless steel
wetted parts and either a NPT threaded or ASME B16.5 2-in. to
8-in. flanged process connection.
B.9 Hazardous locations certifications
B.9.1 American and Canadian approvals
Factory Mutual (FM) explosion-proof approval
E5
Project ID: 3012658
Explosion-proof for Class I, Div. 1, Groups A, B, C, and D
Temperature Class: T6
Enclosure: Type 4X
(See also
Instructions specific to hazardous area installations
).
Canadian Standards Association (CSA)
explosion-proof approval
E6
Project ID: 1786345
Explosion-proof for Class I, Div. 1, Groups A, B, C, and D
Temperature Class: T6
Enclosure: Type 4X
Single Seal
See also
Instructions specific to hazardous area installations
.
Instructions specific to hazardous area installations (E5 and E6)
Model numbers covered:
2130**9E***********E5***,2130**9E***********E6***
2130**9M***********E5***,2130**9M***********E6***
(“*” indicates options in construction, function and materials – see
The following instructions apply to equipment covered by CSA and
FM explosion-proof approvals:
1. The equipment may be used with flammable gases and
vapors with apparatus Class 1, Div 1, Groups A, B, C and D.
2. CSA and FM explosion-proof approved versions of the
2130***E
are certified for use in ambient temperatures of
–58 to 167 °F (–50 to 75 °C), and with a maximum process
temperature of 500 °F (260 °C).
CSA and FM explosion-proof approved versions of the
2130***M
are certified for use in ambient temperatures of
–40 to 167 °F (–40 to 75 °C), and with a maximum process
temperature of 356 °F (180 °C).
3. Installation of this equipment shall be carried out by suitably
trained personnel, in accordance with the applicable code of
practice.
4. Inspection and maintenance of this equipment shall be
carried out by suitably trained personnel, in accordance with
the applicable code of practice.
5. The user should not repair this equipment.
6. The certification of this equipment relies upon the following
construction materials:
Body:
Aluminum alloy (ASTM B85 360.0) or 316 stainless steel
Cover:
Aluminum alloy (ASTM B85 360.0) or 316 stainless steel
Probe:
316 stainless steel, or alloy C276 (UNS N10276) and alloy C
(UNS N10002)
Probe Filling:
Perlite
Cover Seal:
Silicone
7. If the equipment is likely to come into contact with
aggressive substances, it is the responsibility of the user to
take suitable precautions that prevent it from being
adversely affected, thus ensuring that the type of protection
is not compromised.
Aggressive Substances – e.g. acidic liquids or gases that may
attack metals or solvents that may affect polymeric
materials.
Suitable Precautions – e.g. regular checks as part of routine
inspections or establishing from the material’s data sheet
that it is resistant to specific chemicals.
The metallic alloy used for the enclosure material may be at
the accessible surface of this equipment; in the event of rare
accidents, ignition sources due to impact and friction sparks
could occur. This shall be considered when the Rosemount
2130 is installed in locations that specifically require Class 1,
Div 1 equipment.
8. It is the responsibility of the user to ensure:
a. The voltage and current limits for this equipment are
not exceeded.
b. That the joint requirements between the probe
(switch) and the vessel tank are compatible with the
process media.
Содержание Rosemount 2130
Страница 1: ...Reference Manual 00809 0100 4130 Rev DC January 2019 Rosemount 2130 Level Switch Vibrating Fork ...
Страница 2: ...ii Section Title January 2019 Reference Manual 00809 0100 4130 Rev DC ...
Страница 8: ...iv Reference Manual 00809 0100 4130 Rev DC Contents January 2019 Contents ...
Страница 14: ...6 Reference Manual 00809 0100 4130 Rev DC Introduction January 2019 Introduction ...
Страница 76: ...Reference Manual 00809 0100 4130 Rev DC Product Certifications January 2019 68 Product Certifications ...
Страница 77: ......