Programming the UC12PG-R Controller on the PMAC II Solo Panel

Overview • 11

sweat heaters and input values. The UC12PG-R also aver-

ages and logs heater run times, and displays hourly, daily, 
weekly, and monthly run time averages.

1.5.7.1. Viewing Status Screens

1. Log into the UC12PG-R as instructed in 

Sec-

tion 1.5.3., 

Logging Into the UC12PG-R

.

2. The Main Configuration screen should be 

visible (

Figure 1-12

). Use the 

 and 

 

buttons to move the cursor to 

1. STATUS

Press the 

 button to select and open the 

first Status screen.

3. From the Status View screen, press the 

 

button to move the cursor to 

1. VIEW TIME 

& DATE

 and press the 

 button to select 

and view.

This screen displays the current date and time of the 

controller. 

4. Press the 

 or 

 button to go back to the 

Status View screen.

5. From the Status View screen, press the 

 

button to move the cursor to 

2. VIEW 

SPACE TEMP

 and press the 

 button to 

select and view.

This screen displays the current space temperature.

6. Press the 

 or 

 button to go back to the 

Status View screen.

7. From the Status View screen, press the 

 

button to move the cursor to 

3. VIEW DEW-

POINT

 and press the 

 button to select 

and view.

This screen displays the current inside dewpoint tem-

perature.

8. Press the 

 or 

 button to go back to the 

Status View screen.

Figure 1-39 - Status View Screen (First Screen)

Figure 1-40 - Complete Status View Menu

NOTE: Only four lines at a time are visible 
through the PMAC II Solo keypad window.

1.VIEW TIME & DATE
2.VIEW SPACE TEMP
3.VIEW DEWPOINT

4.VIEW MIN DEWPOINT

1.VIEW TIME & DATE
2.VIEW SPACE TEMP
3.VIEW DEWPOINT
4.VIEW MIN DEWPOINT
5.VIEW MAX DEWPOINT
6.VIEW MIN PULSE %
7.VIEW MAX PULSE %
8.VIEW LOAD SHED

9.VIEW LOAD SHED %
10.SOTWARE VERSION 

Figure 1-41 - Time and Date Status Screen

Figure 1-42 - Time and Date Status Screen

Figure 1-43 - Dewpoint Status Screen

     00 / 00 / 00

   

      

     00 : 00 : 00

      SPACE TEMP
   

      

         84F

      DEW POINT
   

      

         77F

Содержание PMAC II Solo

Страница 1: ...Pulse Modulating and Anti Sweat Control PMAC II Solo Installation and Operation Manual 026 1503 Rev 0 ...

Страница 2: ......

Страница 3: ...uite 100 Kennesaw GA 30144 USA Phone 770 425 2724 Fax 770 425 9319 Please Note This manual covers only the PMAC II Solo P N 851 1104 model If information is needed on the PMAC II network version consult the PMAC II manual P N 026 1501 ...

Страница 4: ......

Страница 5: ...O PANEL 4 1 5 1 Keypad 4 1 5 2 How the Setpoints Work 4 1 5 3 Logging Into the UC12PG R 4 1 5 4 Entering Changing Setpoints 5 1 5 4 1 Setting Time Date 5 1 5 4 2 Setting Dewpoints 6 1 5 4 3 Setting Pulse Percentages 6 1 5 4 4 Setting Load Shed 7 1 5 4 5 Setting Temperature and RH Offsets 7 1 5 4 6 Setting the Sensor Fail Output 7 1 5 5 Alarms 8 1 5 5 1 Navigating the Alarm Screens 8 1 5 5 2 Viewin...

Страница 6: ......

Страница 7: ...el to control of all anti sweat heaters channels based on dewpoint calculated from relative humidity and temperature inputs without need for a central CPC site control system The UC12PG R does not support multiple zone control All heaters are controlled by the same setpoint and dew point inputs 1 1 Features Full Solid State Control Quiet Operation Easily added to existing systems Controlled by the...

Страница 8: ...rom doors windows vents heaters and outside walls that could affect temperature readings The sensor should be be tween four and six feet from the floor In addition the sen sor should not be mounted above other sensors that generate heat during operation such as relative humidity sensors To mount the sensor use a screwdriver to press in the tab on the left side of the sensor enclosure and lift the ...

Страница 9: ...II Solo panel The necessary connections between this terminal strip and the UC12PG R controller are hard wired by CPC during man ufacturing 1 3 2 1 Wiring for RH Sensor 1 3 2 2 Sensor Cable Type Wire the sensors to the PMAC II Solo terminal strip us ing Belden 8641 or equivalent for the temperature sensor and Belden 8771 or equivalent for the humidity sensor 1 3 2 3 Wire Connections Figure 1 9 sho...

Страница 10: ... Dewpoint setpoint the heaters will op erate at the percentage specified in the Minimum Pulse Percentage setpoint When the dewpoint is between the minimum and maximum setpoint the PMAC II Solo s pulse percentage varies between the Minimum Pulse Per centage and 100 the higher the dewpoint the higher the pulse percentage Finally if the dewpoint meets or ex ceeds the Maximum Dewpoint setpoint the hea...

Страница 11: ...to 1 SET TIME AND DATE and press the button to select Use the or buttons to access all the date and time values in the Date and Time Configuration screen Figure 1 15 2 Press the or buttons to move the cur sor to the month field of the current date Use the and buttons to set the month 01 12 3 Press the or buttons to move the cur sor to the days field of the current date Use the and buttons to set t...

Страница 12: ...e button to select 10 Use the or buttons to adjust the set point to the desired minimum dewpoint level 11 Press the button to save changes and go back to the Configuration screen 12 Use the or buttons to select 3 SET MAX DEWPOINT and use the and buttons to adjust the setpoint to the desired maximum dewpoint level 13 Press the button to save changes and go back to the Setpoints Configuration screen...

Страница 13: ...n to save and go back to the Config uration screen 18 From the Configuration screen press the button to scroll down the list to 8 SET RH OFFSET and press the button to select Use the and buttons to add or sub tract an offset from the humidity sensor read ing Press the button to save and go back to the Configuration screen 1 5 4 6 Setting the Sensor Fail Output Setting the Sensor Fail Output is the...

Страница 14: ...w any text that is not visi ble on screen 1 5 5 2 Viewing the Alarm Screens 3 View an alarm by using the and but tons to choose an alarm from the alarm log list Press the button to select and view The alarm screen Figure 1 27 shows the number the alarm appears in the log the name of the alarm the time and date it was recorded and the alarm status Active or Cleared 4 Once an alarm has been viewed a...

Страница 15: ...oller to reboot 1 5 6 Percentage On Times Percent On Time shows the average duty cycle on time that the anti sweat outputs have been operating at For example if the outputs have operated at 0 for half an hour and 100 for the next half hour the Hour Percent On Time would show 50 Setting Zero On Time to Active manually resets all calculations 1 5 6 1 Viewing the Percentage On Time Screens 1 Log into...

Страница 16: ...en press the button to move the cursor to 4 ON LAST MONTH and press the button to select and view The Average Output for Month gives the average run time percentage of the outputs for every month The calcu lation starts at midnight on the first day of each month and is restarts at the beginning of each month 10 The screen displays the average output per centage for the most recent week of opera ti...

Страница 17: ... move the cursor to 2 VIEW SPACE TEMP and press the button to select and view This screen displays the current space temperature 6 Press the or button to go back to the Status View screen 7 From the Status View screen press the button to move the cursor to 3 VIEW DEW POINT and press the button to select and view This screen displays the current inside dewpoint tem perature 8 Press the or button to...

Страница 18: ... screen 15 From the Status View screen press the button to move the cursor to 7 VIEW MAX PULSE and press the button to select and view This screen displays the maximum pulse rate generated at the maximum dewpoint setpoint 16 Press the or button to go back to the Status View screen 17 From the Status View screen press the button to move the cursor to 8 VIEW LOAD SHED and press the button to select ...

Страница 19: ...0 SOFTWARE STATUS and press the button to select and view This screen displays the version of the software 22 Press the button to go back to first Status View screen Figure 1 39 or the button to go back to the last Status View screen you were on 23 Press the button once to go back to the Main Configuration screen Figure 1 12 and twice to go back to the default home screen Figure 1 49 Load Shed Pul...

Страница 20: ...Programming the UC12PG R Controller on the PMAC II Solo Panel Overview 14 ...

Страница 21: ......

Страница 22: ... Climate Technologies Retail Solutions Inc and or its affiliates collectively Emerson reserves the right to modify the designs or specifications of such products at any time without notice Emerson does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any product remains solely with the purchaser and end user 02...

Отзывы: