PCM-22 Rotary Knife Controller
36
© EMERSON Motion Control
A c t u a l T o r q u e
M a x T o r q u e
=
A p p l i e d V o l t a g e
1 0 V D C
Bipolar Sync
When set to Bipolar Sync, this parameter allows for direct movement of
the FX drive motor ratioed to the sync encoder. This mode moves the
motor shaft in direct response to encoder or drive signals. This means
immediate velocity without ramping in your FX drive. If the Master axis
accelerates very quickly, your FX drive (Follower axis) will try to follow
just as quickly. Too fast an acceleration by the Master axis could result
in “F” (Following Error) faults for the Follower axis.
Bipolar Sync Ratio(Motor)
This parameter is the relationship of the
Follower axis
position to the
Master axis
position.
For example:
If you set it to three, for every revolution of the Master axis there will be
three revolutions of the Follower axis. Thus, the bipolar sync ratio would
be 3:1.
Содержание PCM-22
Страница 8: ......
Страница 18: ...PCM 22 Rotary Knife Controller 10 EMERSON Motion Control ...
Страница 40: ...PCM 22 Rotary Knife Controller 32 EMERSON Motion Control Figure 17 Master Axis Screen for an Encoder ...
Страница 74: ...PCM 22 Rotary Knife Controller 66 EMERSON Motion Control ...
Страница 87: ...P N 400274 01 Revision A7 79 ...