PCM-22 Rotary Knife Controller
78
© EMERSON Motion Control
6) Decrease the DG gain by increments of 0x1.
The length and phase variation should be re-checked after any
of the six possible adjustments above.
Once the total phase variation is reduced as much as possible, the final
adjustment if desired, is the
Phase Correction Dead Band
(
PH0
serial
command
)
. See
Follower Cycles
Once this is accomplished,
Phase Correction Limit
, does not need to
change unless there are large
Follower Length
or sensor position
changes due to a machine or product change.
Note:
The value of
FM7
plus
FM8
is tested against the
Phase Distance
Error Limit (+)
and
Phase Distance Error Limit (-)
to activate the
In Phase output. An alternate way of minimizing phase
variation is to monitor the
In Phase
, output function 24 and
adjust
Phase Correction Limit
slowly while reducing the
Phase
Distance Error Limit(+)
and
Phase Distance Error Limit(-)
to the
performance desired. This is a better approach for high speed
applications because of the inherent latency of serial
commands.
See
Issues
Maintaining Phase
in
Tips and Troubleshooting
.
Содержание PCM-22