I N S T R U C T I O N M A N U A L R E V 4 . 2
8
SYSTEM SPECIFICATIONS
REMOTE CONTROL UNIT:
Enclosure
Panel mounted IP65/NEMA4X Dimensions:
197X146.6X68.5mm (7.75" X 5.77"
X2.7")
.
Approvals
CE and UL Listed
Digital Display
LED backlight, Instant and Average Opacity -5 to 99% Opacity
Ambient Temperature Range
0 to +50
o
C (+32 to + 122
o
F)
Power Requirements
Power 20.4 to 28.8VDC < 10% ripple, 20va
Alarm Time Delay & set point
Field programmable.
Alarm Reset
Manual or Automatic
Analog Outputs (4)
Four 12-bit Analog outputs 4-20mA, Field selectable range -5.0 to 100%.
Ch1 and Ch2 Individually field selectable for Instant % opacity, or 6 minute
average with z/s checks or without checks for process control.
Exit Correlation (Lx / Lt)
0.3~1.0 OPLR
Calibration check options
Selectable internal timed or computer initiates or push button on demand.
Communication
Remote access, RS485 MODBUS networking.
Battery Backup
7 years typical
Содержание OPM4001
Страница 31: ...I N S T R U C T I O N M A N U A L R E V 4 2 30 ABOUT PAGE About page displays the basic setup information ...
Страница 36: ...I N S T R U C T I O N M A N U A L R E V 4 2 35 ANALOG OUTPUT CONNECTIONS ...
Страница 52: ...I N S T R U C T I O N M A N U A L R E V 4 2 51 OPM6127 1OF3 CONTROL UNIT TO SENSOR WIRING DUAL BLOWER ...
Страница 53: ...I N S T R U C T I O N M A N U A L R E V 4 2 52 OPM6127 2OF3 CONTROL UNIT TO SENSOR WIRING SINGLE BLOWER ...
Страница 54: ...I N S T R U C T I O N M A N U A L R E V 4 2 53 OPM6127 3OF3 CONTROL UNIT TO SENSOR WIRING NO BLOWER ...