6. Align the clevis pin holes in the downrod with the

holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 2). The
clevis pin must go through the holes in the motor
coupling and the holes in the downrod. Push the
straight leg of the hairpin clip through the hole near
the end of the clevis pin until the curved portion of
the hairpin clip snaps around the clevis pin. The
hairpin clip must be properly installed to prevent
the clevis pin from working loose. 

7. Install the setscrew (supplied) in the motor coupling

and tighten using the 5/32” setscrew wrench
(supplied) (Figure 2).

8. Screw two 1-1/4” threaded studs (supplied) into the

motor (Figure 3). Leave approximately 7/8” of the
stud extending above the motor. Coil the wires and
wire connectors around the motor coupling, then
slide the coupling cover over the downrod and
rotate the cover until the threaded studs protrude.
Install two lockwashers (supplied) and knurled
knobs (supplied) to secure the cover to the motor.
All wires and wire connectors must be enclosed
under the coupling cover.

NOTE: Lightly snug the knurled knobs and make
sure the wires and wire connectors are completely
inside the coupling cover and not pinched between
the coupling cover and the motor.

SETSCREW

CLEVIS PIN

MOTOR
COUPLING

DOWNROD

HAIRPIN
CLIP

MOTOR COUPLING

HAIRPIN
CLIP

CLEVIS
PIN

DOWNROD

CONNECT YELLOW WIRES 
USING WIRE CONNECTOR

SETSCREW

CLEVIS
PIN

Figure 2

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed could result in the fan falling.

WARNING

!

9. Position the ceiling cover over the downrod. Be

sure the cover is oriented correctly, with the large
opening at the top (Figure 4).

10. Reinstall the hanger ball on the downrod

as follows. Route the motor leads through the
hanger ball and slide the hanger ball over the
downrod (Figure 4). Install the pin through the
holes at the top of the downrod and slide the
hanger ball up the downrod, aligning the ball so the
pin is captured in the groove in the top of the
hanger ball. Pull the hanger ball up tight against the
pin and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.

11. The blue, black, white, and yellow leads exiting

the downrod are 80-inches long. Before installing
the fan, measure up approximately 6 to 9-inches
above the ball/downrod assembly. Cut off excess
leads and strip back insulation 1/2-inch from end
of leads.

CEILING COVER

SETSCREW

PIN

HANGER BALL

DOWNROD

Figure 4

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

KNURLED KNOB

1-1/4" THREADED
STUD

MOTOR

COUPLING COVER

7/8"

LOCKWASHER

Figure 3

Содержание ODYSSEY CF2455BS00

Страница 1: ...READ AND SAVE THESE INSTRUCTIONS Part No F40BP73370000 Form No BP7337 U L Model No CF2455 Model No CF2455BS00 CF2455ORB00 CF2455PW00 ODYSSEY Net Weight 26 0 Lbs 54 Ceiling Fan Owner s Manual ...

Страница 2: ...s provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to p...

Страница 3: ...ILING COVER FAN BLADES MOTOR COUPLING COVER LIGHT KIT ADAPTER UPLIGHT LEAD ASSEMBLY BLADE HOLDER CAPS LEFT LIGHT KIT PLATE ASSEMBLY SW116 FAN LIGHT WALL CONTROL HANGER BALL DOWNROD ASSEMBLY HANGER BRACKET SW105 RECEIVER LOOSE PARTS BAG LIGHT KIT GLASS DIE CAST GLASS HOLDERS FAN MOTOR AND HOUSING ASSEMBLY BLADE HOLDER CAPS RIGHT HI MED LOW FAN OFF REV EMERSON D L U L Do not install or use fan if an...

Страница 4: ...cuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qua...

Страница 5: ...CLIP CLEVIS PIN DOWNROD CONNECT YELLOW WIRES USING WIRE CONNECTOR SETSCREW CLEVIS PIN Figure 2 It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened Failure to verify that the pin and setscrew are properly installed could result in the fan falling WARNING 9 Position the ceiling cover over the downrod Be sure the cover is oriented correct...

Страница 6: ...nector and the one pin connector from the motor shaft Figure 7 17 Securely connect the black wire from the light kit plate assembly to the blue wire from the motor shaft using a wire connector supplied Figure 7 Connect the white wire from the plate assembly to the white wire from the motor shaft using a wire connector supplied SINGLE PIN CONNECTOR SETSCREW COLLAR FOUR PIN CONNECTOR LIGHT KIT ADAPT...

Страница 7: ...sing the same procedure LEFT BLADE HOLDER CAP FLANGE ASSEMBLY 10 32 X 3 8 PAN HEAD SCREW 2 PER HOLDER CAP RIGHT BLADE HOLDER CAP Figure 10 21 You have now completed the initial assembly of your new ceiling fan You can now proceed with hanging and wiring your fan CEILING FLOOR AT LEAST 7 Figure 11 The fan must be hung with at least 7 of clearance from floor to blades Figure 11 WARNING 1 Securely at...

Страница 8: ...nect the electrical supply circuit before installing the fan and light kit or receiver 1 Pull the wire leads coming from the end of the downrod and the supply wires through the open side of the hanger bracket Figure 14 2 Position the SW105 Receiver supplied in the ceiling cover so that the flat side of the receiver faces up and the open portion of the receiver is to the right as shown in Figure 14...

Страница 9: ... outlet box push the black blue and yellow wires into the other side of the outlet box Figure 15 Final Assembly 1 Screw the two 1 1 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 16 2 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 17 3 Secure the ceiling cover in place by installing two lockw...

Страница 10: ...the stud threads revealed 10 LIGHT KIT ADAPTER LIGHT KIT GLASS KNURLED KNOB SCREW ROTATE LIGHT KIT GLASS COUNTERCLOCKWISE VIEWED FROM TOP Figure 21 12 Your ceiling fan is now installed and wired and ready for use DIE CAST GLASS HOLDER PROTECTIVE COVER ON ADHESIVE BACKED MATERIAL Figure 18 DIE CAST GLASS HOLDER LIGHT KIT GLASS Figure 19 TURN KNURLED KNOB SCREW SEVERAL TURNS INTO THE GLASS HOLDER LI...

Страница 11: ... Wall Control and Receiver Figure 22 Your wall control and receiver have code switches which must be set in one of 16 possible code combinations The four levers numbered 1 2 3 and 4 on the switches are factory set in the ON up position Change the switch settings as follows 1 Slide the four switch levers in the wall control to your choice of ON up or down positions Use a ball point pen or small scr...

Страница 12: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if no installed and used in accordance with the instructions may cause harmful interference to radio communications However there is not guarantee that interference will not occur in a particular installatio...

Страница 13: ... weight and result in smoother operation Or use supplied balancing kit to balance blades Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage t...

Страница 14: ...14 4 2 1 3 5 6 7 10 3 11 25 8 7 31 30 29 15 15 20 21 22 23 24 28 27 12 13 14 8 26 9 HI MED LOW FAN OFF REV EMERSON D L U L 17 16 18 17 19 Repair Parts ...

Страница 15: ...der 763265 3 763265 7 763265 6 26 Uplight Lead Assembly 761790 761790 761790 Loose Parts Bag containing 763243 763243 1 763243 1 3 Threaded Stud 8 32 x 1 1 4 4 5 Wire Connector 7 6 Setscrew Wrench 5 32 7 Lockwasher 4 8 Knurled Knob 4 11 Clip Hairpin 12 Pin Clevis 13 Setscrew 17 Blade Screw 10 32 x 3 8 21 24 Phillips Head Screw 8 32 x 3 8 3 25 Setscrew Wrench 3 16 27 Knurled Knob Screw 2 28 Jumper ...

Страница 16: ...ized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass glob...

Отзывы: