11. Remove the three switch housing mounting

screws (Figure 4) from the switch housing plate.
Position the switch housing assembly on the
switch housing plate and align the holes in the
switch housing assembly with the holes in the
plate. Secure the switch housing assembly by
installing the three mounting screws (Figure 5).

NOTE: Do not pinch wires between the switch
housing assembly and the switch housing plate.

12. You have now completed the assembly of your

new ceiling fan. You can now proceed with hang-
ing and wiring your fan.

MOUNTING SCREWS (3)

SWITCH
HOUSING
ASSEMBLY

Figure 5

SWITCH
HOUSING
ASSEMBLY

SWITCH HOUSING
CONNECTOR

MOTOR CONNECTOR

Figure 4

Electrical Requirements

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capa-
ble of withstanding a load of at least 50 pounds.

1. Securely attach the hanger bracket to the outlet

box using the two screws supplied with the outlet
box. (Figure 7.)

How to Hang Your

Ceiling Fan

AT LEAST

7'

CEILING

FLOOR

Figure 6

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 2

Figure 7

To reduce the risk of fire, electric shock, or personal injury,
mount fan to outlet box marked acceptable for fan support,
and use screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not accept-
able for fan support and may need to be replaced. Consult a
qualified electrician if in doubt.

WARNING

!

Turning off wall switch is not sufficient. To avoid possible
electrical shock, be sure electricity is turned off at the main
fuse box before wiring. All wiring must be in accordance
with National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible electri-
cal shock.

WARNING

!

The fan must be hung with at least 7' of clearance from
floor to blades (Figure 6).

Hanger bracket must seat firmly against outlet box. If the
outlet box is recessed, remove wall board until bracket con-
tacts box. If bracket and/or outlet box are not securely
attached, the fan could wobble or fall.

To reduce the risk of fire, electric shock, or personal injury,
mount fan to outlet box marked acceptable for fan support,
and use screws supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not accept-
able for fan support and may need to be replaced. Consult a
qualified electrician in in doubt.

To avoid fire or shock, follow all wiring instructions carefully.
Any electrical work not described in these instructions
should be done or approved by a licensed electrician.

The outlet box must be securely anchored and capable of with-
standing a load of at least 50 lbs.

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

Содержание NORTHWIND CF705AB03

Страница 1: ...with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible fo...

Страница 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Страница 3: ... provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proc...

Страница 4: ... the end of the clevis pin until the curved por tion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to pre vent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed 4 Back off the jam nut until it rests loosely against the setscrew head Install the setscrew in the motor coupling Figure 1 and tighten...

Страница 5: ...or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accept able for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turne...

Страница 6: ...ire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE B...

Страница 7: ...r bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box and or secure securely fastened outlet box 6 Fan blades out of balance 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan Your fan mod...

Страница 8: ...carding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Flor...

Отзывы: