background image

2

WARNING

!

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel

disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off

the power to the ceiling fan before servicing.

4. Do not put anything into the fan blades while they are turning.

5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not

operate fan without blades.

2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if

Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible
electrical shock. Electrical installation should be made or approved by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50

pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting
screws provided with the outlet box. Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.

4. The downrod furnished with the fan provides the minimum recommended floor to fan blade

clearance for an 8 foot ceiling.

5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental

contact with the fan blades.

6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do

not know enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not

specifically approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any

accessories designated specifically for use with this product by Emerson. Substitution of parts or
accessories not designated for use with this product by Emerson could result in personal injury or
property damage.

WARNING: 

To Reduce the risk of personal injury, do not bend the blade flange when installing the

blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep

it in a safe place for future use.

Содержание NORTHWIND CF705AB03

Страница 1: ...with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible fo...

Страница 2: ...y U L outlet boxes listed as acceptable for fan support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceili...

Страница 3: ... provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing contact your local retail er or catalog outlet for replacement before proc...

Страница 4: ... the end of the clevis pin until the curved por tion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to pre vent the clevis pin from working loose Pull on the hanger ball to make sure the clevis pin is properly installed 4 Back off the jam nut until it rests loosely against the setscrew head Install the setscrew in the motor coupling Figure 1 and tighten...

Страница 5: ...or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not accept able for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turne...

Страница 6: ...ire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE B...

Страница 7: ...r bracket and or ceiling outlet box is not 5 Tighten the hanger bracket screws to the outlet box and or secure securely fastened outlet box 6 Fan blades out of balance 6 Interchanging an adjacent side by side blade pair can redistribute the weight and result in smoother operation WARNING For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan Your fan mod...

Страница 8: ...carding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 EMERSON Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Flor...