BIOS
NITX-300-ET-DVI Installation and Use (6806800N97A)
69
Table 5-14 COM0 Console Redirection Settings
Field
Description
COM0 (PCI Bus2,Dev10,Func1)
Console Redirection Settings
Terminal Type
Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set.
VT100+: Extends VT100 to support color, function keys, etc. VT-
UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more
bytes. Items: VT100, VT100+, VT-UTF8, ANSI. Default is VT100.
Bits per second
Selects serial port transmission speed. The speed must be
matched on the other side. Long or noisy lines may require lower
speeds. Items: 9600, 19200, 57600, 115200. Default is 115200.
Data Bits
Selects the data bits. Items: 7, 8. Default is 8.
Parity
A parity bit can be sent with the data bits to detect some
transmission errors. Even: parity bit is 0 if the num of 1's in the data
bits is even. Odd: parity bit is 0 if num of 1's in the data bits is odd.
Mark: parity bit is always 1. Space: Parity bit is always 0. Mark and
Space Parity do not allow for error detection. They can be used as
an additional data bit. Items: None, Even, Odd, Mark, Space.
Default is None.
Stop Bits
Stop bits indicate the end of a serial data packet. (A start bit
indicates the beginning). The standard setting is 1 stop bit.
Communication with slow devices may require more than 1 stop
bit. Items: 1, 2. Default is 1.
Flow Control
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can be
sent to stop the data flow. Once the buffers are empty, a 'start'
signal can be sent to re-start the flow. Hardware flow control uses
two wires to send start/stop signals. Software flow control uses
start/stop ASCII chars, which slows down the data flow and can be
problematic if binary data is being sent. Items: None, Hardware
RTS/CTS. Default is None.
Recorder Mode
On this mode enabled only text will be send. This is to capture
Terminal data. Items: Disabled, Enabled. Default is Disabled.
Resolution 100x31
Enables or disables extended terminal resolution. Items: Disabled,
Enabled. Default is Enabled.
Legacy OS Redirection
On Legacy OS, the Number of Rows and Columns supported
redirection. Items: 80x24, 80x25. Default is 80x24.
Содержание NITX-300-ET-DVI
Страница 10: ...NITX 300 ET DVI Installation and Use 6806800N97A 10 List of Figures ...
Страница 32: ...Hardware Preparation and Installation NITX 300 ET DVI Installation and Use 6806800N97A 32 ...
Страница 90: ...BIOS NITX 300 ET DVI Installation and Use 6806800N97A 90 ...
Страница 92: ...Operating System and Driver Support NITX 300 ET DVI Installation and Use 6806800N97A 92 ...
Страница 95: ...Replacing the Battery NITX 300 ET DVI Installation and Use 6806800N97A 95 ...
Страница 96: ...Replacing the Battery NITX 300 ET DVI Installation and Use 6806800N97A 96 ...
Страница 98: ...Related Documentation NITX 300 ET DVI Installation and Use 6806800N97A 98 ...
Страница 108: ...NITX 300 ET DVI Installation and Use 6806800N97A Sicherheitshinweise 108 ...
Страница 109: ......