2. Gently lift the transmitter on the feed through until it disengages from the notches
on the feed through. You will not be able to remove the transmitter completely.
3. Rotate the transmitter to the desired position.
CAUTION
Do not rotate the housing more than 360°. Excessive rotation can damage the
wiring and cause measurement error or flowmeter failure.
4. Lower the transmitter, sliding it onto the notches on the feed through.
5. Replace the clamping ring on the feed through. Tighten the screw to 28 in lbf
(3.16 N m)– 32 in lbf (3.62 N m).
CAUTION
Ensure that the connection between the transmitter and the sensor is moisture-
proof. Inspect and grease all gaskets and O-rings. Moisture in the electronics can
cause measurement error or flowmeter failure.
2.6
Rotating the display orientation
The user interface orientation for the 4200 transmitter can rotate 360° in 90° increments
by software selection.
Using the display, select
Menu
>
Configuration
>
Display Settings
>
Rotation
.
Mounting and sensor wiring
Installation Manual
April 2019
MMI-20058013
18
Micro Motion
®
4200 2-Wire Transmitter
Содержание Micro Motion 4200
Страница 1: ...Installation Manual MMI 20058013 Rev AB April 2019 Micro Motion 4200 2 Wire Transmitter ...
Страница 4: ...Contents Installation Manual April 2019 MMI 20058013 4 Micro Motion 4200 2 Wire Transmitter ...
Страница 10: ...Planning Installation Manual April 2019 MMI 20058013 10 Micro Motion 4200 2 Wire Transmitter ...
Страница 32: ...Wiring the channels Installation Manual April 2019 MMI 20058013 32 Micro Motion 4200 2 Wire Transmitter ...
Страница 34: ...Power up the transmitter Installation Manual April 2019 MMI 20058013 34 Micro Motion 4200 2 Wire Transmitter ...