30
Micro Motion
®
Model 3711 Gas Flow Computers
Setting Up Communications
4.5.2
Configuring ROCLINK 800 communications parameters
If you will connect to the Model 3711 using the Connect function, ROCLINK 800 communications
parameters must be configured. Because ROCLINK 800 can be used to connect to multiple devices,
communications parameters are saved separately for each device.
Note: PC COM port parameters are automatically adjusted by ROCLINK 800 as required.
To configure ROCLINK 800 communications parameters for the Model 3711:
1. Start ROCLINK 800 software, but do not connect to a device.
2. Using the Device Directory window in ROCLINK 800 (see Figure 2-2), right-click the device
defined for your Model 3711 (see Section 2.6), then click
Properties
. The ROCLINK 800
Communication Parameters dialog box shown in Figure 4-3 is displayed.
Figure 4-3
ROCLINK 800 Communication Parameters dialog box – General panel
3. In the General panel, set connection parameters as required (see Table 4-3). Note:
•
Tag
,
Device Address
, and
Device Group
identify the Model 3711 that you are
connecting to. The values entered here must match the values configured for the
Model 3711 in the Device Information dialog box (see Section 3.4).
•
Host Address
and
Host Group
will be used by the Model 3711 to identify this host when
formatting responses to requests.
Содержание Micro Motion 3711
Страница 32: ...24 Micro Motion Model 3711 Gas Flow Computers ...
Страница 44: ...36 Micro Motion Model 3711 Gas Flow Computers ...
Страница 56: ...48 Micro Motion Model 3711 Gas Flow Computers ...
Страница 68: ...60 Micro Motion Model 3711 Gas Flow Computers ...
Страница 92: ...84 Micro Motion Model 3711 Gas Flow Computers ...
Страница 108: ...100 Micro Motion Model 3711 Gas Flow Computers ...
Страница 140: ...132 Micro Motion Model 3711 Gas Flow Computers ...
Страница 196: ...188 Micro Motion Model 3711 Gas Flow Computers ...
Страница 210: ...202 Micro Motion Model 3711 Gas Flow Computers ...
Страница 233: ......