5.8
Menu 3 - Timer
This parameter is used to configure and control the Timer Unit.
The Timer Unit control word is a bit-mapped parameter, as shown in the table below:
Parameter
Range
Default
Type
S.03.001
Timer Unit Control Word
0000000000 to
1101111100
0000000000
RW
Bin
US
S.03.002
Timer Unit Status Word
000 to 111
RO
Bin
ND
NC
S.03.003
Timer Unit Timer Counter
0 to 65535
0
RW Num
S.03.004
Timer Unit Wrap Around Limit
0 to 65535
0
RW Num
US
S.03.005
Timer Unit Capture Cache
0 to 65535
RO
Num
RW
Read /
Write
RO
Read
only
Num
Number
parameter
Bit
Bit
parameter
Txt
Text
string
Bin
Binary
parameter
FI
Filtered
ND
No default
value
NC
Not
copied
PT
Protected
parameter
RA
Rating
dependent
US
User
save
PS
Power-
down save
DE Destination
IP
IP address
Mac
Mac
address
SMP
Slot menu
parameter
S.03.001
Timer Unit Control Word
Minimum
0 (Display: 0000000000)
Maximum
892 (Display: 1101111100)
Default
0 (Display: 0000000000)
Units
Type
16 Bit User Save
Update Rate
Immediate
Display Format
Binary
Decimal Places
0
Coding
RW, BU
Bit Description
0 to 2
Event Task Schedule:
Selects the event task that will be scheduled when the Timer Event Flag
(
(
S.03.002
) b0) is set:
•
0 = No Event task scheduled
•
1 = Schedule Event0 task
•
2 = Schedule Event1 task
•
3 = Schedule Event2 task
•
4 = Schedule Event3 task
3
Enable Timer:
•
0 = Timer is disabled
•
1 = Timer is enabled
4
Clock Source:
•
0 = Internal clock
•
1 = External clock provided on digital input (DigIn1 or DigIn2, b9 depending)
5 to 6
Internal Clock Rate:
•
0 = 50 MHz
•
1 = 12.5 MHz
•
2 = 3.125 MHz
•
3 = 0.78125 MHz
Содержание MCi210