4.

Thread the white and black wires of the light fitter
through the cover, lockwasher, hex nut and then
secure by using a wrench.

5.

Connect the white wire from the ceiling fan to the
white wire of the light fitter. Connect the blue wire
from the ceiling fan to the black wire of the light
fitter. Use listed wire connectors (previously
removed in Step 3) to make connections. (Figures
6 and 7.)

WIRE
CONNECTORS

WHITE WIRE

WHITE WIRE

BLUE WIRE

BLACK WIRE

FAN SWITCH
CHAIN

SWITCH
HOUSING

LOCKWASHER

HEX NUT

SCREWS

COVER

LIGHT FITTER

FINIAL
(sold separately)

ADJUSTABLE 
LIGHT FITTER

FAN SWITCH 
CHAIN

BOWL CAP

Figure 6

7.

Carefully tuck all wires and splices into the switch
housing.

8.

Install the cover and fitter assembly to the switch
housing by using the three screws removed in
Step 2.

9.

Gently place the glass bowl onto the light fixture
(Figure 8). Then place the finial (sold separately)
onto the threaded light fixture. Tighten the taller
finial nut (supplied with finial) onto the threaded
light fixture.

10.

Install three 13-watt medium base compact
fluorescent bulbs into the light sockets.

11. If installing an optional frame:

Gently slide the

frame over the glass bowl then secure the frame
to the light fixture by placing the hex nut, finial and
shorter finial nut (both sold separately) onto the
threaded light fixture. Tighten the finial nut onto
the threaded light fixture (Figure 9).

NOTE: The 9” pull chain extending from the light fixture
is without a chain coupling attached, two chain
couplings are included and pre-installed to the
9” extension pull chain located in the parts bag.

12.

Connect the wood pendant (supplied) to the
switch pull chain by sliding the wood pendant
(small hole first) onto the pull chain. Attach the
chain coupling to the end of the chain and allow
the wood pendant to fall down over the
coupling.

To avoid possible fire or electrical shock, be careful
not to pinch wires between the switch housing and
the light fitter.

WARNING

!

Figure 7

WARNING:

To avoid possible fire or electrical

shock, make certain no bare wire strands are
exposed outside wire connectors. 

4

FRAME (OPTIONAL)

GLASS BOWL

HEX NUT & FINIAL (sold separately)

FINIAL NUT (Shorter Nut)
(sold separately)

Figure 9

GLASS BOWL

FINIAL (sold separately)

FINIAL NUT (Taller Nut)
(sold separately)

Figure 8

Installation on Emerson Fans

Having Two-Piece Die-Cast

Switch Housings

1.

Remove all parts and parts packages from carton.

2.

Remove the cover from switch housing below
ceiling fan (Figure 6).

3.

Carefully pull down white and blue wires from the
switch housing and remove wire connectors.

NOTE: Wet location plate can not be used with two-
piece die-cast switch housing.

NOTE: The FN100 

finial pack (sold separately)

comes with three options: no holes, one hole and
two holes for pull chain options

.

6.

Depending on the model purchased, insert the fan
speed control switch chain through the offset hole
in the glass bowl or the hole in the bowl cap.

Содержание LK70

Страница 1: ...D AND SAVE THESE INSTRUCTIONS Ceiling Fan Light Fixture Owner s Manual Part No F40BP74180000 Form No BP7418 Net Weight 3 5 Lbs UL Includes Three 13 Watt CFL Bulbs and F480WW Fitter Model Numbers LK70 LK80 ...

Страница 2: ...al shock install only on Emerson CF Series Ceiling Fans Assembly and Installation 4 Remove the center screw from the switch cup Figure 1 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch cup and remove the wire connectors from the wires 6 Insert the black and white wires from the light fitter through the center hole in the switch cup Figure 2 and thread the switch...

Страница 3: ... NUT Taller Nut sold separately Figure 4 NOTE The FN100 finial pack sold separately comes with three options no holes one hole and two holes for pull chain options NOTE Two finial nuts are supplied with FN100 kit Use the taller finial nut when a frame is not being installed 14 Gently place the glass bowl onto the light fixture Figure 4 Then place the finial sold separate ly onto the threaded light...

Страница 4: ...ded light fixture Figure 9 NOTE The 9 pull chain extending from the light fixture is without a chain coupling attached two chain couplings are included and pre installed to the 9 extension pull chain located in the parts bag 12 Connect the wood pendant supplied to the switch pull chain by sliding the wood pendant small hole first onto the pull chain Attach the chain coupling to the end of the chai...

Страница 5: ...ely until the canopy fits snugly against the ceiling Figure 12 5 LIGHT FIXTURE HEX NUT BUSHING CAP BUSHING THREADED ROD EXTENSION Figure 10 CANOPY THREADED ROD EXTENSION LOCKWASHER HEX NUT Figure 11 CANOPY KNURLED KNOB 2 THREADED STUD 2 MALE BRACKET Figure 12 Figure 16 WARNING To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors 5 Install...

Страница 6: ...careful not to pinch wires between light fitter assembly cover and the ceiling WARNING 8 Carefully tuck all wires and splices into the outlet box 9 Attach the canopy light fixture assembly to the female bracket by first pushing threaded rod into center hole of the male bracket outlet box assembly then tighten to ceiling mount kit by turning clockwise tightening the threaded rod extension until sec...

Страница 7: ...son Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or d...

Страница 8: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74180000 Printed in China 12 09 Form No BP7418 ...

Отзывы: