background image

2

Safety Instructions

WARNING:

To avoid fire, shock, and serious personal injury, follow all instructions carefully.

1.Read your Owner's Manual carefully before installing the light fixture. Retain Owner's Manual for

future reference.

2.Be careful of the fan and blades when cleaning, painting, or working near the fan. Before installing

or servicing the light fixture or ceiling fan, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.

3.Do not exceed the wattage indicated on fixture.

ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION

1.To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker

box before wiring.

2.Make certain no bare wires are exposed outside the wire connectors.

3.All wiring must conform to national and local electrical codes.

4.Follow the recommended instructions for the proper method of wiring your new light fixture. If you

feel you do not have enough electrical wiring knowledge or experience, have your light fixture
installed by a licensed electrician. Any electrical work not described in this manual should be
performed by a licensed electrician.

WARNING:

To reduce the risk of possible fire and electrical shock, install only on Emerson CF

Series Ceiling Fans.

Assembly and Installation

4.

Remove the center screw from the switch cup
(Figure 1).

5.

Carefully locate the white and blue wires (labeled
either "L" or "LIGHT") in the switch cup and
remove the wire connectors from the wires.

6.

Insert the black and white wires from the light fitter
through the center hole in the switch cup
(Figure 2) and thread the switch cup onto the light
fitter. Hold wires taut while installing switch cup to
prevent the wires from twisting. Tighten the fitter
until the fan switch chain aligns with the hole in the
fitter.

7. If installing in a wet location:

Install the light

fitter on plate using the lockwasher, nut and
rubber washer supplied with wet location plate.
Place the rubber washer on the top of the wet
location plate, then place the light fitter through the
center hole of the wet location plate, secure with
lockwasher and nut (Figure 2).

Do not install or use the light fixture if any part
is missing or damaged. Contact your dealer for
replacement.

SCREWS

CENTER SCREW

SWITCH
CUP   

MOTOR
CONNECTOR

COVER PLATE

SWITCH CUP
CONNECTOR

Figure 1

Installation on Emerson Fans

Having a Modular Switch Cup with

Center Screw

1.

Remove all parts and parts packages from the
carton.

2.

Remove the switch cup from the cover plate by
removing the three screws around the side of the
switch cup (Figure 1).

3.

Disconnect the motor connector from the switch
cup connector (Figure 1).

WARNING

!

To avoid possible electrical shock, be sure
electricity is turned off at the main fuse or
circuit breaker box before wiring.

WARNING

!

Содержание LK70

Страница 1: ...D AND SAVE THESE INSTRUCTIONS Ceiling Fan Light Fixture Owner s Manual Part No F40BP74180000 Form No BP7418 Net Weight 3 5 Lbs UL Includes Three 13 Watt CFL Bulbs and F480WW Fitter Model Numbers LK70 LK80 ...

Страница 2: ...al shock install only on Emerson CF Series Ceiling Fans Assembly and Installation 4 Remove the center screw from the switch cup Figure 1 5 Carefully locate the white and blue wires labeled either L or LIGHT in the switch cup and remove the wire connectors from the wires 6 Insert the black and white wires from the light fitter through the center hole in the switch cup Figure 2 and thread the switch...

Страница 3: ... NUT Taller Nut sold separately Figure 4 NOTE The FN100 finial pack sold separately comes with three options no holes one hole and two holes for pull chain options NOTE Two finial nuts are supplied with FN100 kit Use the taller finial nut when a frame is not being installed 14 Gently place the glass bowl onto the light fixture Figure 4 Then place the finial sold separate ly onto the threaded light...

Страница 4: ...ded light fixture Figure 9 NOTE The 9 pull chain extending from the light fixture is without a chain coupling attached two chain couplings are included and pre installed to the 9 extension pull chain located in the parts bag 12 Connect the wood pendant supplied to the switch pull chain by sliding the wood pendant small hole first onto the pull chain Attach the chain coupling to the end of the chai...

Страница 5: ...ely until the canopy fits snugly against the ceiling Figure 12 5 LIGHT FIXTURE HEX NUT BUSHING CAP BUSHING THREADED ROD EXTENSION Figure 10 CANOPY THREADED ROD EXTENSION LOCKWASHER HEX NUT Figure 11 CANOPY KNURLED KNOB 2 THREADED STUD 2 MALE BRACKET Figure 12 Figure 16 WARNING To avoid possible fire or electrical shock make certain no bare wire strands are exposed outside wire connectors 5 Install...

Страница 6: ...careful not to pinch wires between light fitter assembly cover and the ceiling WARNING 8 Carefully tuck all wires and splices into the outlet box 9 Attach the canopy light fixture assembly to the female bracket by first pushing threaded rod into center hole of the male bracket outlet box assembly then tighten to ceiling mount kit by turning clockwise tightening the threaded rod extension until sec...

Страница 7: ...son Light Fixture should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or d...

Страница 8: ...Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74180000 Printed in China 12 09 Form No BP7418 ...

Отзывы: