8
U.L. Model No.: LK65
4. Installation on Emerson Fans Having a
Modular Switch Housing with Center Screw
(continued)
4.8
Connect the Switch Housing White Wire to the
Light Fixture Assembly White Wire using one of the
previously removed Wire Connectors (Figure 9).
Connect the Switch Housing Blue Wire to the Light
Fixture Assembly Black Wire using one of the
previously removed Wire Connectors (Figure 9).
LIGHT FIXTURE
ASSEMBLY BLACK WIRE
LIGHT FIXTURE
ASSEMBLY WHITE
WIRE
SWITCH
HOUSING
WHITE WIRE
SWITCH
HOUSING
BLUE WIRE
WIRE
CONNECTOR
WIRE
CONNECTOR
LIGHT FIXTURE
ASSEMBLY PLATE
Figure 9
To avoid possible fire or electrical shock, make
certain no bare wire strands are exposed outside wire
connectors.
WARNING
!
4.9
Reconnect the Motor Connector to the Switch Housing
Connector (Figure 10).
Carefully tuck all Wires and Connectors into the Switch
Housing (Figure 10).
Position the Switch Housing/Light Fixture Assembly
onto the Cover Plate.
Reinstall the Three Screws (previously removed in
Step 4.2) and tighten securely (Figure 10).
MOTOR
CONNECTOR
SWITCH HOUSING
CONNECTOR
SWITCH
HOUSING
SCREWS (3)
COVER PLATE
LIGHT FIXTURE
ASSEMBLY PLATE
Figure 10
To avoid possible fire or electric shock, be careful not
to pinch wires between switch housing and the cover
plate.
WARNING
!