background image

5

9.

Screw the eye screw (supplied) into the joist
7 inches from the center of the ceiling outlet box
(Figure 6).

10. Carefully lift the fan and seat the hanger

ball/downrod assembly on the hanger bracket
that was just attached to the outlet box (Figure 7).
Be sure the groove in the ball is lined up with the
tab on the hanger bracket (Figure 5).

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 5

7"

EYE SCREW

OUTLET BOX

Figure 6

OUTLET

BOX

HANGER

BRACKET

HANGER BALL/

DOWNROD 

ASSEMBLY

NOTE: CEILING COVER,

SUPPLY WIRES AND

FAN WIRES OMITTED

FOR CLARITY.

Figure 8

11. Connect the green grounding wire from the

hanger ball, the green grounding wire from
the hanger bracket, and the green grounding wire
from the fan to the grounding conductor of the
supply (this may be a bare wire or wire with green
colored insulation). Securely connect wires with
wire connectors (supplied) (Figure 8).

12. Securely connect the fan motor white wire to the

supply white (neutral) wire using wire connector
supplied (Figure 8). Securely connect the fan
motor black wire to the supply black (hot) wire
using wire connector supplied (Figure 8). After
connections have been made, turn leads upward
and carefully push the leads into the outlet box,
with the wires spread apart and the white and
green leads on one side of the outlet box and the
black leads on the other side of the outlet box.

13. Screw the two 3/4” threaded studs (supplied) into

the tapped holes in the hanger bracket (Figure 8).

14. Lift the ceiling cover up to the threaded studs and

turn until studs protrude through the holes in the
ceiling cover (Figure 9).

15. Secure the ceiling cover in place by sliding

lockwashers over the threaded studs and
installing the two knurled knobs (supplied)
(Figure 9). Tighten the knurled knobs securely
until the ceiling cover fits snugly against the
ceiling. Your fan is now wired to be turned on and
off from the wall switch.

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.

NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.

WARNING

!

THREADED
STUD (2)

HANGER
BRACKET

WHITE 
SUPPLY 
(NEUTRAL)

GREEN WIRE (GROUND) 
FROM HANGER BRACKET

LISTED WIRE 
CONNECTOR (3)

SUPPLY GROUND 
WIRE

GREEN WIRE 
(GROUND) FROM 
HANGER BALL

BLACK FAN WIRE

BLACK 
SUPPLY
(HOT)

WHITE
FAN WIRE

GREEN WIRE 
(GROUND) FROM FAN 

Figure 8

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

WARNING

!

Содержание HF1160WW 00

Страница 1: ...n authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The gl...

Страница 2: ...lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades 5 Suitable for use with solid stat...

Страница 3: ...s CAUTION The blade assemblies must be mounted on the motor assembly so that the This Side Up label is visible at the top of the motor Figure 1 1 Install one blade assembly on the top of the motor assembly using two M6 1 0 x 12mm Phillips hex head screws two split lockwashers and two flat washers supplied Figure 1 Repeat this procedure for the remaining two blade assemblies Electrical Requirements...

Страница 4: ... yoke It is critical that the clevis pin in the motor yoke is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly instal...

Страница 5: ...and green leads on one side of the outlet box and the black leads on the other side of the outlet box 13 Screw the two 3 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 8 14 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 9 15 Secure the ceiling cover in place by sliding lockwashers over the th...

Страница 6: ... cable through the eye screw and then back through the two cable clamps CAUTION It is important to note the proper installation position of the cable clamps as illustrated in Figure 10 TO obtain maximum holding power install U bolt section of clip on dead or short end of cable and saddle on long end of cable Improper installation reduces the efficiency of the connection by as much as 40 percent 17...

Страница 7: ...ad Knurled M4 7 x 10mm 2 14 Lockwasher External Tooth M4 2 15 Wrench Setscrew 16 Clamp Safety Wire 2 17 Screw Eye 18 Cover Ceiling 762516 3 762516 15 19 Cover Motor 762494 762494 1 20 Capacitor 4 5 uF 762493 762493 21 Blade set of 3 762495 762495 1 22 Flange set of 3 762497 762497 1 Owner s Manual BP7272 BP7272 Before discarding packaging material be certain all parts have been removed HOW TO ORDE...

Страница 8: ...15 16 10 11 12 5 6 13 17 21 20 22 14 19 T H I S S I D E U P Part No F40BP72720000 Printed in Taiwan 02 04 Form No BP7272 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Repair Parts ...