background image

1. The pressure limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.

II 1 G Ex h IIC T6 Ga

II 2 G Ex h IIC T6 Gb

II 1 G Ex h ia IIC T5 Ga

Specifications

The Specifications section lists the specifications for the Enardo 2000 and Enardo 2500 Series. Specification is stamped 

on the nameplate attached to the emergency relief vent. Refer to Product Identification and Marking section for the 

nameplate details.

Connection Sizes Available

  See Table 1

Pressure Ranges

(1)(2)

Enardo 2000 Series:

2.0 to 32.0 oz./sq. in.  

(0.5 oz./sq. in. increments)  

3.5 to 55.0 in. w.c. 

(1.0 in. w.c. increments) 

8.6 to 138 mbar 

(2.2 mbar increments)

Enardo 2500 Series:

4.0. to 16.0 oz./sq. in.  

(0.5 oz./sq. in. increments) 

7.0 to 27.0 in. w.c. 

(0.5 in. w.c. increments) 

17.4 to 67.2 mbar 

(2.2 mbar increments)

Vacuum Pressure Ranges

(1)

 (2500 Series)

0.5, 0.75, 1 and 2 oz./sq. in.

Construction Materials

Enardo 2000 Series

Base and Arm:

 Carbon Steel, 304 Stainless steel and 

316 Stainless steel

Disk and Seal Support:

 Aluminum,  

304 Stainless steel and 316 Stainless steel

Seal:

 Buna-N, FEP Teflon

®

 and Viton

®

Enardo 2500 Series

Base, Arm and Hood:

 Carbon steel,  

304 Stainless steel and 316 Stainless steel

Disk and Seal Support

: Aluminum and 316 Stainless steel 

Seal:

 FEP Teflon

®

, Viton

®

 and Buna-N

Vacuum Spring:

 302 Stainless steel

Vacuum Pallet and Vacuum Seat:

 Polyphenylene Sulfide 

and 316 Stainless steel

Certification

EN IEC 60079-0:2018

EN IEC 60079-11:2012

EN ISO 80079-36:2016

EN ISO 80079-37:2016

OUTER HOUSING OF STAINLESS STEEL, 

CARBON STEEL OR COATED ALUMINUM 

OUTER HOUSING OF UNCOATED ALUMINUM 

SMART WIRELESS ID MARKING 

(ENARDO 2000 SERIES MODELS ONLY)

HAZARDOUS LOCATION

Figure 4. 

Product Identification and Marking

Table 1. 

Connection sizes and Model Number

SERIES

MODEL

CONNECTION SIZE

ANSI

API

Enardo 2000 Series

Emergency Pressure Relief -  

For Pressure Relief Only

2004

4 in.

- - - -

2008

8 in.

8 in.

2012

12 in.

- - - -

2016

16 in.

- - - -

2018

18 in.

- - - -

2020

20 in.

20 in.

2024

24 in.

24 in.

Enardo 2500 Series

Emergency Pressure Relief Vent 

with Vacuum -

For Pressure and Vacuum Relief

2516

16 in.

- - - - 

2520

20 in.

20 in.

2524

24 in.

24 in.

Teflon

®

 and Viton

®

 are marks owned by E. I. du Pont de Nemours and Company.

2

Enardo 2000 and Enardo 2500 Series

Outside North 

America Only

Содержание FISHIER Enardo 2000 Series

Страница 1: ...n Either condition may result in equipment damage or personal injury Only a qualified person shall install or service the emergency pressure relief vent Figure 1 Enardo 2000 Series Emergency Pressure Relief Vent Figure 2 Enardo 2500 Series Emergency Pressure Relief Vent with Vacuum Figure 3 Enardo 2000 Series with Smart Wireless Monitoring Introduction Scope of the Manual This Instruction Manual p...

Страница 2: ...um 304 Stainless steel and 316 Stainless steel Seal Buna N FEP Teflon and Viton Enardo 2500 Series Base Arm and Hood Carbon steel 304 Stainless steel and 316 Stainless steel Disk and Seal Support Aluminum and 316 Stainless steel Seal FEP Teflon Viton and Buna N Vacuum Spring 302 Stainless steel Vacuum Pallet and Vacuum Seat Polyphenylene Sulfide and 316 Stainless steel Certification EN IEC 60079 0...

Страница 3: ...Number Product Identification and Marking Hazardous Locations Fisher Emergency Pressure Relief Vents are available with outer housings of carbon steel stainless steel or aluminum as indicated in Figure 4 Nameplate A nameplate is attached to the vent and contains the following information Model Number Ex 2024 24T 1 Connection Flange Size 24 in Serial Number Tag Number Optional Notified Body Number ...

Страница 4: ... of the EPRV a proximity sensor and a wireless transmitter The built in proximity sensor detects the open or closed position using a magnetic target located on the arm assembly on the hinged end A signal is sent to the wireless transmitter which can then be sent to a control room via any WirelessHART Gateway This wireless sensor networking technology is based on the Highly Addressable Remote Trans...

Страница 5: ...s Follow the instruction below for the installation of the Enardo 2000 and Enardo 2500 Series Install the Enardo 2000 and Enardo 2500 Series on the flange bolt patterns that match with bolt pattern of the vent The attachment flange base should be at level surface 1 Carefully remove the Enardo 2000 and Enardo 2500 Series from its crate The seal portion of the vents is delicate protect this surface ...

Страница 6: ...nder pressure Follow the instruction below for the preventive maintenance of the Enardo 2000 and Enardo 2500 Series 1 Loosen fasteners on top of the vent and remove the hood and the spring chamber 2 Inspect and clear away any debris or buildup that may cause the vent to become lodged or impede air flow through the unit Do not adjust the height of the installed spring Clean the internal components ...

Страница 7: ...ns when cleaning the transmitter The surface resistivity of the antenna assembly is greater than 1 GΩ To avoid electrostatic charge build up it must not be rubbed or cleaned with solvents or dry cloth vent can achieve depends on the individual vent size and material Minimum settings are reached when the unit is installed by itself However when weights are added to the arm of the unit elevated pres...

Страница 8: ... 30 D103818X012 2015 2021 Emerson Process Management Regulator Technologies Inc All rights reserved 12 21 The Emerson logo is a trademark and service mark of Emerson Electric Co All other marks are the property of their prospective owners Fisher is a mark owned by Fisher Controls International LLC a business of Emerson Automation Solutions The contents of this publication are presented for informa...

Отзывы: