Quick Start Guide
D103470X012
DLC3020f Digital Level Controller
April 2022
6
Mounting
Mounting the 249 Sensor
The 249 sensor is mounted using one of two methods, depending on the specific type of sensor. If the sensor has a
caged displacer, it typically mounts on the side of the vessel as shown in the left image in figure 3. If the sensor has a
cageless displacer, the sensor mounts on the side or top of the vessel as shown in the right image in figure 3.
TYPICAL CAGED SENSOR MOUNTING
TYPICAL CAGELESS SENSOR MOUNTING
Figure 3. Typical Mounting
LIQUID LEVEL
The DLC3020f digital level controller is typically shipped attached to the sensor. If ordered separately, it may be
convenient to mount the digital level controller to the sensor and perform the initial setup and calibration before
installing the sensor on the vessel.
Note
Caged sensors have a rod and block installed on each end of the displacer to protect the displacer in shipping. Remove these parts
before installing the sensor to allow the displacer to function properly.