Key

 

Description

 

Part Number

 

Key

 

Description

 

Part Number

 

17

 

Machine Screw (2 required)

 

 

29

 

Screw, Steel (Not shown)

 

 

 

Steel, for brass yoke

 

1H526928982

 

 

Type 1301F with handwheel and steel

 

 

 

302 Stainless steel, for Stainless steel yoke

 

1J926938992

 

 

spring case only

 

1E985428982

 

18

 

Locknut

 

 

30

 

Washer, Steel (Not shown)

 

 

 

Type 1301F

 

 

 

Type 1301F with handwheel and steel

 

 

 

Brass (for 

standard 

spring case)

 

1A518014012

 

 

spring case only

 

1L449428982

 

 

Steel (for Stainless steel spring case)

 

1A352224122

 

32

 

Mounting Bracket (Not shown)

 

 

 

Type 1301G

 

 

 

Yoke mounted

 

22A6305X012

 

 

Zinc-plated steel

 

1A354024122

 

 

Casing mounted

 

1U9284X0012

 

19

 

Diaphragm Locknut, Aluminum

 

1A309324122

 

33

 

Bracket Cap Screw (2 required)

 

 

21

 

Top Connector, 316 Stainless steel

 

 

 

Use with key 32 (Not shown)

 

1C631224052

 

 

Use with Stainless steel yoke only

 

1J926035072

 

34

 

Bracket Mounting Washer

 

 

22

 

Valve Disk Collar

 

 

 

Use with key 32 (Not shown)

 

T12861T0012

 

 

304 Stainless steel

 

1D468635032

 

35

 

NACE Tag

 

 

 

316 Stainless steel (NACE)

 

1D4686X0012

 

 

Use with NACE unit (Not shown)

 

- - - - - - - - - - -

 

24

 

Handwheel (Not shown)

 

 

36

 

Tag Wire

 

 

 

Type 1301F

 

1L217544992

 

 

Use with key 35 (Not shown)

 

- - - - - - - - - - -

 

26

 

Vent Screen (Not shown)

 

 

38*

 

Body O-ring (Not shown)

 

 

 

Type 1301F, 18-8 Stainless steel

 

0L078343062

 

 

Use with -65°F / -54°C Cold Service Unit

 

ERAA03305A1

 

 

Type 1301G, 304 Stainless steel

 

0W086343062

 

 

Use with -80°F / -62°C Cold Service Unit

 

ERAA03305A0

 

27

 

Mounting Post (3 required) (Not shown)

 

 

39*

 

Top Connector O-ring (Not shown)

 

 

 

Type 1301F T-handle panel mounting only,

 

 

 

Use with -65°F / -54°C Cold Service Unit

 

14B8848X012

 

 

316 Stainless steel

 

1F2449X0022

 

 

Use with -80°F / -62°C Cold Service Unit

 

ERAA03307A0

 

 

Type 1301G panel mounting only, Steel

 

1L2629X0012

 

40

 

Pipe Plug (Not shown)

 

 

28

 

Mounting Screw, Brass (3 required)

 

Use with key 27 (Not shown)

 

 

0V070414012

 

 

Brass

 

Stainless steel

 

1C333528992

 

1C3335X0012

 

 
 

*Recommended spare part.

 

 

Содержание Fisher 1301 Series

Страница 1: ...in equipment damage or personal injury Use qualified personnel when installing operating and maintaining the 1301 Series high pressure regulator Introduction Scope of the Manual This Instruction Manual provides instructions for the installation adjustment maintenance and parts ordering of the Types 1301F and 1301G high pressure regulators Product Description Types 1301F and 1301G regulators are di...

Страница 2: ...r Liquid Polytetrafluoroethylene PTFE Disk 1000 psig 69 0 bar Nylon PA Disk Water 1000 psig 69 0 bar Other Liquids 2000 psig 138 bar Outlet Pressure Ranges See Table 1 Maximum Emergency Outlet Pressure 1 Type 1301F 250 psig 17 2 bar Type 1301G 550 psig 37 9 bar Wide Open Flow Coefficients for Relief Valve Sizing Cg 5 0 Cv 0 13 C1 38 5 IEC Sizing Coefficients XT 0 938 FD 0 50 FL 0 85 Recovery Coeff...

Страница 3: ... 6 17 1301G 200 to 500 13 8 to 34 5 Silver 1K156027142 0 331 8 41 0 88 22 4 1 All springs can be backed off to 0 psig 0 bar Principle of Operation The 1301 Series regulators are direct operated Downstream pressure is registered internally through the body to the underside of the diaphragm When downstream pressure is at or above set pressure the disk is held against the orifice and there is no flow...

Страница 4: ...d outlet pressure is factory set at the midpoint of the regulator spring range If pressure adjustment is necessary refer to the Startup section In all cases check the spring setting to make sure it is correct for the application Overpressure Protection The 1301 Series regulators have an outlet pressure rating lower than their inlet pressure rating If actual inlet pressure can exceed the outlet pre...

Страница 5: ...e halves are a matched set and need to be kept together 10 Unscrew the orifice key 5 Examine seating edge of orifice Replace with a new part if worn or nicked Assembly This procedure assumes that the regulator was completely disassembled If not start these instructions at the appropriate step Key numbersused are shown in Figure 3 for the Type 1301F regulator and in Figure 4 for the Type 1301G regu...

Страница 6: ...l com 6 22 10 NOTE OPTIONAL THIRD OUTLET Figure 3 Type 1301F High Pressure Regulator Assembly 15 2 18 11 9 19 8 16 7 21 1 12 4 13 17 14 5 3 BP6341 A CN7095_C Figure 4 Type 1301G High Pressure Regulator Assembly Figure 5 Exploded View of The DiaphragmHead Assembly and Yoke 15 18 2 9 11 8 19 7 16 17 1 12 13 4 14 5 3 6 22 10 CD3923_F 19 8 7 13 17 4 40 S 20 ...

Страница 7: ...pring 1D387325072 1K155725072 1B798525062 1K155828982 1 Body 1 4 NPT Connection 302 Stainless steel Inconel X750 NACE 1D387137022 15A3522X012 Brass 2 outlet port 39A1342X012 11 Spring Zinc plated steel Brass 3 outlet port CF8M Stainless steel 2 outlet port ERAA00584A0 32B4291X022 Type 1301F 0 to 75 psig 0 to 5 2 bar Blue 1D387227022 CF8M Stainless steel 3 outlet port 1 4 x 1 2 in Flanged Connectio...

Страница 8: ...eel Use with key 32 Not shown 1C631224052 Use with Stainless steel yoke only 1J926035072 34 Bracket Mounting Washer 22 Valve Disk Collar Use with key 32 Not shown T12861T0012 304 Stainless steel 1D468635032 35 NACE Tag 316 Stainless steel NACE 1D4686X0012 Use with NACE unit Not shown 24 Handwheel Not shown 36 Tag Wire Type 1301F 1L217544992 Use with key 35 Not shown 26 Vent Screen Not shown 38 Bod...

Отзывы: