Emerson DIXELL XWEB1000D PRO Скачать руководство пользователя страница 7

 

1592010820 XWEB5000 PRO STP GB r1.0 18.03.2022.docx                                                     XWEB5000 PRO                                                                   

   7/20 

 

5. 

INSTALLATION 

 

5.1  XWEB 

For  installation,  the  XWEB  system  must  not  be  opened  in  any  way.  If  the  box  is  opened,  the  warranty  will 
lapse.  

 

XWEB can be installed in various ways based on the type of user interface access that you wish to provide 
for  the  final  user.  Below  is  a  description  of  the  most  complete  procedure,  i.e.  where  the  system's  user 
interface can be used entirely in local control. If the system has already been configured and you wish to use 
the  interface  through  modem  or  Ethernet,  points  5  to  9  may  be  optional.  The  particular  features  of  these 
types of connectivity are described herein. 
 
To set up a local installation of the system, we recommend having the following equipment available: 

  a Phillips and a slot-head screwdriver; 

  a PS2 or USB mouse; 

  a PS2 or USB keyboard; 

  a  monitor  with  a  DVI  or  VGA  connector.  We  recommend  using  high 

definition monitors 

The  system  must  be  installed  referring  to  the  figure  below,  which 
illustrates the rear XWEB panel, and following the points listed here: 

1.  The product has a power plug with protective earth. Make sure that 

the electrical system has a protective earth connection; 

2.  Attach  the  XWEB  device  in  the  position  it  will  be  used  in.  If  it  is 

installed  on  a  table,  set  the  rubber  feet  up  in  the  holes  on  the 
underside of the device. For rack installation, on the other hand, use 
the supplied brackets and screws. 

3.  Connect  it  to  the  power  mains  by  the  supplied  power  cord.  Set  the 

power  plug  up  so  that  it  is  easily  accessible  at  all  times

.

 

Note:

  Do 

not turn the system on; 

4.  Connect  the  RS485,  the  relays  and  digital  inputs,  and  end  and/or 

polarise the line, if necessary; 

5.  Connect any telephone lines and/or LAN network cables; 
6.  Connect any keyboard and mouse; 
7.  Connect any monitors; 
8.  Connect any printers; 
9.  Connect  any  modem:  internal  modem  or  external  modems.  The 

cable must not be any longer than 10 m. 

10.  It is now possible to turn the system on by pressing and releasing; 
 
 
 
 
 
 
 
 
 
 
 

 

For operator safety and to 
protect the XWEB 
system, before 
performing any sort of 
operation, connect the 
system to the electrical 
network by the supplied 
cable. Power cord must 
be the last to be removed. 
 

 

 

Avoid  direct  passage  between 
operators  as  much  as  possible 
(to  avoid  electrostatic  induction 
and subsequent discharges); 

 

If  the  electrical  voltage  supply 
differs  from  the  required  rating, 
this could seriously damage the 
system; 

 

Connection 

errors 

(and 

connections  that  differ  from  the 
prescribed  ones)  can  pose  a 
danger  to  operator  safety  and 
cause  faults  in  the  system  and 
to  the  instruments  that  are 
connected to it; 

 

Insert  one  or  more  easily 
accessible 

disconnecting 

devices  to  the  exterior  of  the 
device  to  separate  the  device 
from the power mains;

 

 

Do  not  use  the  device  in 
environments  with  flammable 
gases. 

 

Do not modify the device in any 
way. 

Содержание DIXELL XWEB1000D PRO

Страница 1: ...XWEB5000 PRO V 1 0 ...

Страница 2: ... 300 400 SERIES 11 5 2 2 CONFIGURATION FOR XJA XJP XJM MODELS 11 6 LOCAL CONNECTIVITY 12 7 REMOTE CONNECTIVITY 12 7 1 GENERAL AND MINIMUM REQUIREMENTS 12 7 2 DESKTOP SOFTWARE REQUIREMENTS PC 13 7 3 SOFTWARE MOBILE REQUIREMENTS SMARTPHONE TABLET 13 7 4 CONNECTIVITY WITH CROSS CABLE 14 7 5 INTRANET CONNECTIVITY OR LAN CONNECTION AND VPN 16 7 6 INTERNET CONNECTIVITY ON PUBLIC IP 17 7 7 WIFI CONNECTIV...

Страница 3: ...age resulting from the use of unsupported devices CAUTION Dixell srl reserves the right to amend this manual without prior notice The latest available version can be downloaded from the internet site CAUTION Immediately after the power failure no new data is recorded all recorded data is kept in non volatile memory The memory is electronic and no data is kept or conveyed to other media such as pap...

Страница 4: ...of 4 July 2012 on Waste Electrical and Electronic Equipment WEEE and to the relevant national implementation regulations we inform you that users of EEE in households there is an obligation not to dispose of WEEE as mixed urban waste and to separate waste collection of WEEE Public or private collection systems required by local laws must be used for disposal It is also possible at the end of its l...

Страница 5: ...he brackets Removable female connectors 2x2ways 2x3ways 1x6ways 4 feet for TABLE mounting 6 Jumpers 1 DVI VGA Converter 1 Installation manual 2 ferrites If one of the following parts is damaged promptly contact your dealer You may also receive a modem or a wifi dongle which will not be included in the same package as a package option When working with a modem connection always check that the type ...

Страница 6: ... of the RTC is 35 ppm the maximum drift of the clock in a year is therefore about 18 minutes Approvals The system consisting of this control and monitoring unit and Dixell temperature meters compliant with the EN13485 standard complies with the EC regulation no 37 2005 and in particular with the EN12830 standard Temperature recorders for the transport and storage and distribution of chilled frozen...

Страница 7: ...holes on the underside of the device For rack installation on the other hand use the supplied brackets and screws 3 Connect it to the power mains by the supplied power cord Set the power plug up so that it is easily accessible at all times Note Do not turn the system on 4 Connect the RS485 the relays and digital inputs and end and or polarise the line if necessary 5 Connect any telephone lines and...

Страница 8: ... without having a screen mouse and keyboard attached For example it is possible to use this initial system installation configuration and then disconnect them definitively if you only intend to set up access from the remote station If you intend to use external peripheral devices always connect them to the unit before turning it on Caution always and only connect the external peripheral devices be...

Страница 9: ...ay attention in Keep the TTL cable away from any source of electromagnetic disturbance Connect each XJ485 module to the instrument with the TTL cable supplied with the module itself Mark the polarity of output 485 which must be respected when connecting the instruments to the network Below is a list of operating tips to obtain the best result in terms of instrument network reliability RS485 serial...

Страница 10: ...disturbance Mount the supplied ferrites on the serial ports as shown in the figure Do not connect the shield of the serial cable to the earth of the electrical system Do not connect the Gnd terminal Draw a map of the installation you are performing it will be useful both in case of problems and in case of future changes the serial line must reach all the stations where the instruments must be cont...

Страница 11: ...he jumper if the XWEB is in the middle of the RS485 line Notes on the use of polarization resistors POL POL In order to avoid false signals on the bus polarization resistors must be inserted It is important to note that they must be inserted in one and only one place in the network otherwise the communication will deteriorate the node in which they are inserted is irrelevant even if it could be co...

Страница 12: ...olution higher than 1024x768 pixels Check your display s instruction manual for supported resolutions 7 REMOTE CONNECTIVITY 7 1 GENERAL AND MINIMUM REQUIREMENTS The user or the installer of XWEB can access its user interface as well as locally with screen keyboard and mouse also through a PC that must be connected and configured to be able to communicate with the XWEB network The XWEB Ethernet por...

Страница 13: ...illa Firefox SUPPORTED 54 All newer computers are capable of meeting these requirements However it is advisable to use the advice of a computer expert to evaluate the computers to be purchased and or already in your possession In the following sections general information on possible network configurations will be provided Right from the start we recommend that you make use of IT experts and or yo...

Страница 14: ...http 192 168 0 200 XWEB default address The connection procedure is complete when the login page opens up Enter user name and password to start using your XWEB Caution a pre requisite to setting the connection up correctly is that the XWEB address and network interface address on your PC need to have a compatible IP class For example with an XWEB network interface configured with 192 168 0 200 the...

Страница 15: ...1592010820 XWEB5000 PRO STP GB r1 0 18 03 2022 docx XWEB5000 PRO 15 20 ...

Страница 16: ...able to assign a valid IP address to the XWEB and be able to provide for your PC any software and credentials if you want to use a VPN network for access Before connecting the XWEB to the network check that the IP address you wish to use for the XWEB is actually free and therefore usable You could perform a PING to that address and if at least one reply is received at the PING the address must be ...

Страница 17: ...ternet you need a public and static IP address which must be specifically requested from your ISP Internet Service Provider Tell your ISP that you want to install a webserver this will help them recognize your needs and provide you with an adequate connection It is highly recommended to obtain all the details of the supply contract for the management of any future connection problems Connection to...

Страница 18: ...ess point XWEB is normally supplied preconfigured in this mode so that the user can search with his PC smartphone tablet to an XWEB PRO SSID network The default password is dixellxwebpro Fixed IP 172 21 0 1 Connection of XWEB to existing Wi Fi network XWEB can be connected via Wi Fi to a Wifi AccessPoint already present on the site In this case you need to temporarily access the XWEB interface wit...

Страница 19: ...2 168 0 14 E mail Address ___________________________ example myXWEB001 company com Modem ___________________________ Telephone number ___________________________ 10 TRADEMARKS Consider It Solved and Intelligent Store are trademarks and Emerson Climate Technologies and the Emerson Climate Technologies logo are service marks and trademarks of Emerson Electric Co Windows and Internet Explorer are re...

Страница 20: ...__________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ ______________________________________________________________________________________ _________________________________________...

Отзывы: