Emerson Dixell XRB60CHC Скачать руководство пользователя страница 7

 

XRB60CHC EN r1.1 2018.11.01.docx 

                           XRB60CHC 

7/7 

 

it  is  possible  to  suffer  continuous  interruption  at  the  communication  channel.  When  discovered,  a  pairing 
secure code will be required for connection. Please follow the APP instruction for more information. 

20.1

 

FIRST INSTALLATION 

After connecting and powering-up the controller, it will be possible to manage it by using the Emerson mobile 
APP. Il will be required to: 

-

 

Install the Emerson mobile APP on your mobile device (smartphone or tablet) 

-

 

Create a new user account (email and password for accessing to the APP) 

The owner is the only account that is able to: 

-

 

Manage the controller via Bluetooth 

-

 

Extend right of access to a particular appliance to other users 

 
A Cloud portal has to be used for: 

-

 

Extend right of access to a particular appliance to other users 

-

 

Select the permission level for any new user 

 
The link for opening the Cloud webpage is on the left side menu of the mobile APP (slide right the screen of 
the  APP  when  on  the 

scan  page  and  follow  the  “Cloud  management”  link.  Please  note  that  the  login  and 

password for the Cloud webpage is the same of the ones used for the mobile APP. 

20.2

 

RESETTING AN APPLIANCE 

In case you need to reset an installation, please follow this operations: 

-

 

Access to the Cloud webpage and select the appliance you want to reset (search for name and 
MAC-ADDRESS) 

-

 

Click on the 

“DELETE” link, the appliance will be removed from the list of owned appliances

 

-

 

Go to the device controller (with the same MAC-ADDRESS) 

-

 

Enter the programming mode 

-

 

Go to the “BLE” menu

 

-

 

Select the par. rPS (reset device ownership) 

-

 

Select “Y” and confirm with

 SET button 

-

 

Exit from the programming menu 

-

 

Logout and login from the mobile APP 

Doing this, the controller will be reset to factory default configuration and it will be ready for a new association 
(means a new Owner) 
 
 

The XRB60CHC is compliant with the following standards:  

ETSI EN 300 328 V2.1.1 (2016-11) 
IEC EN 60730-2-9: 2008 (Third Edition) and Am.1:2011 in conjunction with IEC 60730-1:2010 (Fourth Edition)  
UL  60730-1  Fourth  Edition  and  CAN/CSA-E60730-1:02  Third  Edition  along  with  its  Amendment  1  dated 
February 2007, the Standards for Automatic electrical controls for household and similar use 

 Part 1: General 

requirements. 
 
Hereby,  Dixell  S.r.l.  declares  that  the  radio  equipment  type  XRB60CHC  is  in  compliance  with  Directive 
2014/53/EU. 
 The  full  text  of  the  EU  declaration  of  conformity  is  available  at  the  following  internet  address: 
EmersonClimate.com/Dixell 
 
It therefore meets the essential requirements of the following Directives: 

Radio equipment Directive 2014/53/EU 
Electromagnetic compatibility 2014/30/EU 
Low Voltage equipment 2014/35/EU  

 

The XRB60CHC is compliant with the following standards:  

FCC 15.247 
 

The XRB60CHC is compliant to Part 15 of the FCC Rules: 

Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and  
(2)  this  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 

operation.”

 

 
This device has been designed and complies with the safety requirements for portable (<20cm) RF exposure 
in accordance with FCC rule part 2.1093 and KDB 447498 D01 as demonstrated in the RF exposure analysis.  
Installers  must  ensure  that  this  device  must  not  be  co-located  or  operated  in  conjunction  with  any  other 
antenna or transmitter except in accordance with FCC multi-transmitter product procedures. 
 
Unauthorized repairs, changes or modifications could result in permanent damage to the equipment and void 
your warranty and your authority to operate this device under Part 15 of the FCC Rules. 

 

NOTE:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection  against 
harmful interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the user will be required to correct the interference at 
his own expense. 
 

The XRB60CHC is compliant to RSS 102 
Cet XRB60CHC instrument répond aux normes RSS 102 

 

The Dixell XRB60CHC complies with the safety requirements for RF exposure in accordance with RSS-102 
Issue 5 for portable 
use conditions 

This device complies with ISED’s license

-exempt RSSs. Operation is subject to the following two conditions:  

(1) This device may not cause interference; and  
(2) This device must accept any interference, including interference that may cause undesired operation of the 
device 
This device complies with the safety requirements for RF exposure in accordance with RSS-102 Issue 5 for 
portable use conditions. 
 
Dixell  01XRCHC  est  conforme  aux 

exigences  de  sécurité  pour  l’exposition  RF  conformément

   aux  CNR 

d’Industrie Canada applicables aux appareils radio RSS

-210 5e edition.  

Le présent appareil est conforme aux 

RSS exempts  de licence d’ISDE. Le fonctionnement  de l'appareil est 

sujet aux deux conditions suivantes: 
(1) Ce dispositif ne doit pas produire de brouillage préjudiciable, et 
(2)  Ce  dispositif  doit  accepter  tout  brouillage  reçu,  y  compris  un  brouillage  susceptible  de  provoquer  un 
fonctionnement indésirable. 
 

Le présent appareil est conforme aux limites d’exposition aux RF conformément au norme CNR

-102 émission 

5 pour conditions d’utilisation portable

 

Содержание Dixell XRB60CHC

Страница 1: ...e standard SET POINT SET is used to maintain the temperature at a certain value when the energy saving status ES is not active On the other side when the ES status is active a different SET POINT SET_ES higher than the standard one will be used The parameter HES will have to be set to change the regulation temperature according to the following formula SET_ES SET HES There are also two different d...

Страница 2: ... OR PROBE CONTROLLED MODE Two defrost modes are available timed or controlled by the evaporator s probe A couple of parameters is used to control the interval between defrost cycles idF and its maximum length MdF During the defrost cycle is possible to select some different display indications by using the dFd parameter These modes are available with any kind of defrost type tdF EL electric heater...

Страница 3: ...Press SET UP or wait for 15 sec without pressing any key NOTE1 if there are no parameters in L1 after 3 sec the nP label will be displayed Keep the keys pushed till the L2 message will be displayed NOTE2 the previous set value will be stored even if the programming mode is exited by waiting for the time out to expire MOVE PARAMETERS FROM THE HIDDEN MENU TO THE FIRST LEVEL AND VICEVERSA Each parame...

Страница 4: ...P4 nP no probe the auxiliary relay is switched only by the digital input P1 Probe 1 Thermostat probe P2 Probe 2 evaporator probe P3 do not use it P4 Probe 4 Sdd Auxiliary relay switched off during defrost n Y n the auxiliary relay operates during defrost Y the auxiliary relay is switched off during defrost btA Base Time for timed activation of auxiliary output SEC Min SEC base time is in second At...

Страница 5: ... the right of the appliance card present on the Permissions webpage OTHER Adr Serial address for Modbus communication 1 to 247 bAU Baudrate 9 6 19 2 38 4 57 6 select the correct baudrate for serial communication wired LGC Light button configuration nu not used ES change working mode from normal to energy saving mode and vice versa LiG light output control AUS auxiliary output control dEF defrost c...

Страница 6: ...ections Screw terminal block 2 5 mm2 wiring Power supply according to the model 230Vac 10 50 60Hz 110Vac 10 50 60Hz Power absorption 3 5VA max Display 3 digits red LED 14 2 mm high Inputs up to 4 NTC probes Digital input free voltage contact Relay outputs Compressor SPST 16 5 A or 20 8 A 250VAC Light SPDT 5 2 A 250VAC Fans SPST 8 3 A 250VAC Data storing 8 Kbytes EEPROM Kind of action 1B Pollution ...

Страница 7: ...is compliant with the following standards FCC 15 247 The XRB60CHC is compliant to Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This device has been designed and complies with the safety requirements for p...

Отзывы: