BLUETOOTH COMMUNICATION 

 

The controller implements a Bluetooth 4.2 communication module. This gives 
the possibility to communicate with external devices (for example with a mobile 
APP  able  to  recognize  and  decode  the  device).  All  controllers  use  a  unique 
MAC-ADDRESS, which is used both for identification and communication. The 
communication range is about 5 m (worst case, indoor coverage in presence of 
obstacles).  Over  this  distance  it  is  possible  to  suffer  interruptions  in  the 
communication or  quality  degradation  of  the  communication.  A 6-digit  pairing 
secure  code  can  be  required  for  connection.  Please  follow  the  Emerson 
Connected APP instruction for more information. 

21.1

 

FIRST INSTALLATION 

After installation, it will be possible to manage the controller by using the Emerson Connected APP. Il will be 
required to: 

-

 

Install the Emerson Connected APP on your mobile device (smartphone or tablet) 

-

 

Create a new user account before using the APP 

The owner is the only account that can: 

-

 

Manage the controller via Bluetooth 

-

 

Extend rights of access to a specific appliance also to other users 

 
A Cloud portal will be used for: 

-

 

Extend rights of access to a specific appliance also to other users 

-

 

Select the permission level for any new user 

 
The link for opening the Cloud webpage is on the left side menu of the mobile APP (slide right the screen of 
the APP when on the Device List 

page and follow the “Cloud management” link. Please note that the login and 

password for the Cloud webpage are the same of the mobile APP. 

21.2

 

RESET TO FACTORY DEFAULT 

In case a factory reset is required, please follow these operations: 

-

 

Access to the Cloud webpage and select the appliance you want to reset (search for name 
and/or MAC-ADDRESS) 

-

 

Click on the “DELETE” link, the appliance will be removed from 

the list of owned appliances 

-

 

Go to the device controller (with the same MAC-ADDRESS) 

-

 

Enter the programming mode 

-

 

Go to the “

b

LE” menu

 

-

 

Select the par. 

rPS

 (reset device ownership) 

-

 

Select “Y” and confirm with SET button

 

-

 

Select the par. 

rLi

 (reset device whitelist) 

-

 

Select “Y” and confirm with SET button

 

-

 

Exit from the programming menu 

-

 

Logout and login from the mobile APP 

After this, the controller will be reset to factory default configuration and it will be ready for a new association. 
 
 
 

Содержание DIXELL XR30CHC

Страница 1: ...lways saved in the internal memory to resume previous operation if a power failure occurs It needs the presence of a door switch to work for example i1F dor 4 2 1 PARAMETER INVOLVED i1F or i2F set as door input to monitor the appliance usage StE interval to change from normal to energy saving mode EtS interval to change from energy saving to normal mode HES differential for SETPOINT when energy sa...

Страница 2: ...fter ending the installing operations 10 3 1 ENTER THE PROTECTED LEVEL 1 Enter the Programming mode by pressing SET DOWN buttons for 3 sec C or F LED starts blinking 2 Released the buttons and then search for submenu Pr2 3 Per SET button and then insert the password value 4 Confirm with SET If the password is correct the label Pr2 will blink for some time and then protected parameter menu will be ...

Страница 3: ...he alarm is enabled after the Ad delay time If ALC Ab 55 0 C to ALU or 67 F to ALU If ALC rE 0 0 to 50 0 C or 0 to 90 F AFH Differential for temperature alarm recovery 0 1 to 25 0 C 1 to 45 F differential for alarms ALd Temperature alarm delay 0 to 255 min delay time between the detection of an alarm condition and the relative alarm signalling dot Delay of temperature alarm with door open 0 0 to 2...

Страница 4: ...value visualization ES change working mode from normal to energy saving mode and vice versa LG2 Light button timed 3sec configuration left upper side nu not used LiG light output control AUS auxiliary output control dEF defrost control CC change configuration between NT and LT map ES change working mode from normal to energy saving mode and vice versa UP2 Up button timed 3sec configuration nu not ...

Страница 5: ...ousing self extinguishing ABS Case frontal 32x74 mm depth 60mm Mounting panel mounting in a 71x29mm panel cut out Body Protection IP20 Frontal protection IP65 Terminal blocks Screw terminal block 2 5 mm2 wiring Power supply according to the model 230Vac 10 50 60Hz 110Vac 10 50 60Hz Power absorption 3 5VA max Display 3 digit LED H 14 2 mm Inputs up to 4 NTC PTC or PT1000 probes Digital input up to ...

Страница 6: ...roller via Bluetooth Extend rights of access to a specific appliance also to other users A Cloud portal will be used for Extend rights of access to a specific appliance also to other users Select the permission level for any new user The link for opening the Cloud webpage is on the left side menu of the mobile APP slide right the screen of the APP when on the Device List page and follow the Cloud ...

Отзывы: