Digitax ST User Guide
201
Issue: 5
14.8 EtherCAT interface temperature
Table 14-16 EtherCAT interface temperature
This parameter shows the EtherCAT interface temperature reading in
degrees Celsius.
14.9 EtherCAT interface serial number
Table 14-17 EtherCAT interface serial number
The serial number is loaded into the EtherCAT interface during
manufacture and cannot be changed. It contains the last eight digits of
the 10-digit serial number of the label.
14.10 EtherCAT interface error codes
Table 14-18 EtherCAT interface error codes
If an error is detected during operation the EtherCAT interface will force
a trip on the drive and update the error code parameter (Pr
17.50
14-19 shows the EtherCAT interface error codes.
Table 14-19 EtherCAT interface error codes
14.11 Error handling
The following objects are provided to indicate an error condition
Table 14-20 Error handling objects
14.11.1 Error register
Table 14-21 Error register
14.11.2 Error code
Table 14-22 Error code
EtherCAT interface temperature
Pr
17.44
Default
N/A
Range
0 - 255
Access
RO
EtherCAT interface serial number
Pr
17.35
Default
N/A
Range
0 - 16777215
Access
RO
EtherCAT interface error codes
Pr
17.50
Default
N/A
Range
0 to 255
Access
RO
Error
code
Fault
1
No fieldbus mode has been selected
2
Critical task over-run
3
Invalid feedback source
4
Unknown drive type
5
Unsupported drive type
10
Invalid or missing application
62
Database Initialization error
63
File system Initialization error
64
Error initializing fieldbus stack
74
The EtherCAT interface has overheated
75
The drive is not responding
76
The Modbus connection has timed out
80
Inter-option communication failure
81
Inter-option communication to slot 1 timeout
82
Inter-option communication to slot 2 timeout
83
Inter-option communication to slot 3 timeout
84
Memory allocation error
85
File system error
86
Configuration file error
98
The EtherCAT interface background task has not been
completed
99
Software fault
120
Network loss trip
Index
Name
0x1001
Error_register
0x603F
Error_code
0x1001
Error register
Access: RO
Range:
0 to 255
Size:
Unsigned 8
Unit: N/A
Default: 0
Description:
A non-zero value in this object indicates that an error has
occurred. The bit(s) set indicate the type of error present.
The following bits are supported:
0: Generic error
1: Current
2: Voltage
3: Temperature
When an error is indicated in this object, the particular
error code will be contained in object 0x603F (Error
code).
0x603F
Error code
Access: RO
Range: 0 to
0xFFFF
Size:
Unsigned 16
Unit: N/A
Default: 0
Description:
A non-zero value in this object indicates that an error has
occurred. The value will be one of the codes described in
Table 14-23