Corrective maintenance
10.1
Turbine meter troubleshooting
Use the table below to troubleshoot the turbine meter. Contact the nearest Daniel
Measurement and Control Sales or Service office for repairs. It is important that servicing
be performed by trained and qualified service personnel.
Table 10-1: Troubleshooting
Condition
Probable cause
Correction
No output pulses
from amplifier
module
Input voltage to amplifier below
minimum required for operation
Apply correct voltage (10 - 30 VDC)
Damaged or shorted pickoff
(Resistance across leads should be
600-900 Ohm)
Replace pickoff
Damaged amplifier module
Replace amplifier module
Customer receiver unit not operating
Contact Daniel Customer Service
Meter rotor not turning
Troubleshoot internal assembly
Turbine meter
rotor not turning
Defective rotor bearing
Return rotor assembly to factory for
replacement or repair
Rotor damaged by foreign material
passing through turbine meter
Return rotor assembly to factory for
replacement or repair
Inaccurate
readout
Foreign material on rotor blades
Check and clean blades
Rotor blades are bent
Return to factory for replacement or
repair
Defective accessory equipment
Troubleshoot equipment
(1)
Prepare for mechanical disassembly
for disassembly procedures.
10.2
Verify the return to operational condition
After correcting maintenance issues, verify that the turbine meter is working properly by
following the steps below.
Procedure
1. Inspect all electrical connections to ensure compliance with electrical codes and
safety regulations.
2. Inspect all flange bolts used to secure the turbine meter in-line to ensure that
correct mounting procedures are followed and that flange connections are leak-
free.
3. Evaluate the system setup to ensure that all components are in the correct
sequence for accurate product measurement: isolation valve, strainer, flow
straightener, turbine meter, downstream section, control valve, etc.
User manual
Corrective maintenance
P/N 3-9008-515
March 2019
User manual
99
Содержание Daniel Series
Страница 1: ...User manual P N 3 9008 515 Rev AF March 2019 Daniel Series 1500 Liquid Turbine Meter NPS 3 through 24 ...
Страница 2: ...2 ...
Страница 11: ...Part I Plan User manual Plan P N 3 9008 515 March 2019 User manual 11 ...
Страница 12: ...Plan User manual March 2019 P N 3 9008 515 12 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 69: ...Part II Install User manual Install P N 3 9008 515 March 2019 User manual 69 ...
Страница 70: ...Install User manual March 2019 P N 3 9008 515 70 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 78: ...Testing User manual March 2019 P N 3 9008 515 78 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 79: ...Part III Operate User manual Operate P N 3 9008 515 March 2019 User manual 79 ...
Страница 80: ...Operate User manual March 2019 P N 3 9008 515 80 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 83: ...Part IV Maintain User manual Maintain P N 3 9008 515 March 2019 User manual 83 ...
Страница 84: ...Maintain User manual March 2019 P N 3 9008 515 84 Daniel Series 1500 Liquid Turbine Meter NPS 3 24 ...
Страница 105: ...User manual P N 3 9008 515 March 2019 User manual 105 ...