background image

Crosby

 SerieS BP OMNi-TriM

®

 PreSSure relief valveS

InstallatIon, maIntenance and adjustment InstructIons

© 2017 emerson. all rights reserved.

Emerson.com/FinalControl

Before installation these instructions must be read fully and understood

1 GEnEral

Crosby valves have been tested and adjusted 
at the factory. as service conditions differ it 
may be necessary to make slight adjustments. 
These adjustments are made easily if the 
instructions below are followed carefully.

2 storaGE and handlinG

Often, valves are on hand at the job site months 
before they are installed. unless stored and 
protected properly, valve performance may be 
affected adversely.
rough handling and dirt may damage or 
cause misalignment of the valve parts. it is 
recommended that the valves be left in their 
original shipping containers and that they be 
stored in a warehouse or, as a minimum, on a 
dry surface with a protective covering until they 
are used.

3 installation

3.1 inlet piping

The valve should be mounted vertically in an 
upright position either directly on a nozzle from 
the pressure vessel or on a short connection 
fitting that provides a direct, unobstructed 
flow between the vessel and the valve. 
installing a pressure relief valve in other than 
this recommended position might affect its 
operation adversely. a valve should never be 
installed on a fitting having a smaller inside 
diameter than the inlet connection of the valve. 
Compliance with the above recommendations 
will assure clean, positive valve operation.
Many valves are damaged when first placed 
in service because of failure to clean the 
connections properly when installed.
Both the valve inlet and the vessel and/or line 
on which the valve is mounted must be cleaned 
thoroughly of all dirt and foreign material.

3.2 outlet piping

Discharge piping should be simple and direct. 
a broken connection near the valve outlet is 
preferred. The weight of the discharge piping 
should be carried by a separate support and be 
braced firmly against swaying or vibrations.
fittings or pipe having a smaller inside 
diameter than the valve outlet connections 
must not be used. The flow from the valve must 
discharge to a safe disposal area.

WarninG

To have trouble free performance be sure to clean 
the inlets and outlets of valves thoroughly before 
installing.

The safety of lives and property often depends 
on the proper operation of the pressure relief 
valves. The valves must be maintained according 
to appropriate instructions and must be tested 
periodically and reconditioned to ensure that they 
function correctly.

Crosby pressure relief valves described in this 
instruction are manufactured in accordance 
with the requirements of aSMe Boiler and 
Pressure vessel Code, Section viii. Capacities 
are certified by the National Board of Boiler 
and Pressure vessel inspectors.

engineering Doc. #iS-v3117a

VCioM-06202-En 18/03

Pressure relieving valves must be handled 
carefully and never subjected to sharp impact 
loads. They should not be struck, bumped or 
dropped. rough handling may alter the pressure 
setting, deform valve parts and affect seat 
tightness and valve performance adversely.

notE

Where valves have levers as in Types D and e top 
construction, DO NOT lifT Or CarrY valveS BY THe 
leverS.

inlet and outlet protectors should remain in 
place until the valve is ready to be installed on 
the system.

Содержание CROSBY BP SERIES

Страница 1: ...lure to clean the connections properly when installed Both the valve inlet and the vessel and or line on which the valve is mounted must be cleaned thoroughly of all dirt and foreign material 3 2 Outlet piping Discharge piping should be simple and direct A broken connection near the valve outlet is preferred The weight of the discharge piping should be carried by a separate support and be braced f...

Страница 2: ...instructions Cap Adjusting bolt Adjusting bolt nut Spring washer top Spindle Spring washer bottom Spring Guide Cylinder vent hole Piston O ring Guide O ring Disc holder Disc insert Cylinder O ring Cylinder Base Seal and wire Seat O ring Threaded connection Series BP This vent must remain open ...

Страница 3: ...ur when the valve is reassembled 4 Loosen the base from the cylinder but do not remove 5 Place the valve upside down in a vise and remove the base 6 Remove the guide and disc assembly as a unit A screwdriver or other suitable tool can be inserted into the cylinder vent hole to facilitate removal of the guide 7 Remove the disc holder from the guide 8 Remove the cylinder from the vise and remove the...

Страница 4: ...mbly of caps and lifting lever devices Type A screwed cap Apply pure nickel Never Seez or equivalent to the cap sealing surface and screw the cap onto the top of the cylinder Tighten the cap with a suitable wrench Type B screwed cap with test rod Apply pure nickel Never Seez to the cap sealing surface and screw the cap onto the top of the cylinder Tighten the cap with a suitable wrench Install the...

Страница 5: ...hreads Never Seez Piston O ring Dow Corning 3451 Guide Surface Dow Corning 3451 Guide O ring Dow Corning 3451 Seat O ring Dow Corning 3451 Cylinder O ring Dow Corning 3451 Figure 1 Type E Type D Type A Cap Type B Cap plug Cap plug O ring Cap Cap plug Spindle nut Locknut Cap Cam Cam sleeve O ring Cam sleeve Cam O ring Lever pin Lever View showing valve gagged with test rod Test rod Spindle nut Lock...

Страница 6: ... response delivery service can be initiated by contacting your local Emerson representative Emerson com FinalControl For additional information about Series BP OMNI TRIM pressure relief valves see VCTDS 00594 Neither Emerson Emerson Automation Solutions nor any of their affiliated entities assumes responsibility for the selection use or maintenance of any product Responsibility for proper selectio...

Отзывы: