background image

Product Data Document

420DS-12A

October 1, 2007 - Page 1

Integrated Pump Control 

SCADA RTU

Website:  www.EmersonProcess.com/Remote

Remote Automation Solutions

Benefits

Pre-programmed package eliminates the need 

• 

for custom programming
One package for one to three pumps provides 

• 

consistency for operators and technicians
Local Display/Keypad Operator Interface panel  

• 

for on-site system control
Alarm and historical data reporting for full 

• 

SCADA integration

Multiple pump scenarios allow flexibility to meet 

• 

a wide range of applications
Pump start/stop as well as VFD speed control

• 

Easy-to-use web page station configuration and 

• 

setup

Easily interfaces to field devices and sensors

• 

Security and water quality functions can be 

• 

easily added as needed

Plant managers will take maximum advantage of 

the flexibility and maintenance personnel will ap

-

preciate the simplicity of the Bristol ControlWave 

pump control application.  All remote water and 

wastewater applications have the same require-

ments to automatically control one or more pumps 

to maintain level, pressure and/or flow. Some sites 

may also have the need to control chemical feed, 

measure rain level, and detect intrusion events. All 

of these are pre-programmed and available for use 

to customize for the specific site.

When the application requires modifications or addi

-

tions to the standard program, Bristol ControlWave 

Designer allows unlimited customization by your 

engineering staff or other integrators. 

Single program offers performance and simplicity 

for  monitoring  and  control  of  remote  water  and 

wastewater applications

Well station

• 

Remote tank level control 

• 

Reservoir Control 

• 

Duplex Lift or Booster station

• 

Triplex Lift or Booster station

• 

This standard pre-programmed application lever-

ages our decades of experience monitoring and 

controlling remote pumps in a wide variety of water 

and wastewater sites in North America and through-

out the world.  The standard application can be 

used with the appropriate Bristol

®

 ControlWave

®

 

PLC/RTU, from Emerson Process Management to 

meet the I/O requirements at the various sites. The 

combined solution offers a cost effective system that 

is ready to deploy without the typical programming 

overhead. 

Pre-Engineered Water and Wastewater 

Remote Pump Control Application Package

Содержание Control Wave SCADA RTU

Страница 1: ...o maintain level pressure and or flow Some sites may also have the need to control chemical feed measure rain level and detect intrusion events All of these are pre programmed and available for use to customize for the specific site When the application requires modifications or addi tions to the standard program Bristol ControlWave Designer allows unlimited customization by your engineering staff...

Страница 2: ... 2 tank level DI Intrusion or Motion Digital outputs Pump 1 2 start Pump 1 2 Stop Analog inputs Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level Analog outputs VFD speed control Chemical feed pump Counter inputs Station flow Rain gauge Triplex Booster or Lift Station Digital inputs Pump 1 2 3 status Pump 1 2 3 Remote Local 2 tank level DI Intrusion or Mot...

Страница 3: ...icantly benefiting radio and cellular network architectures Daily Archive Stores 35 days of time stamped minimums maxi mums averages and totals Hourly Archive Stores hourly time stamped minimums maximums averages and totals Trend Archive The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes Setup and Configuration As mentioned earlier the ControlWave pump...

Страница 4: ... taneous values of pressure flow and level Setup and configuration may also be performed from the integral display keypad on the ControlWave PLC RTU SCADA package or via the SCADA system host HMI All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages The configuration pages allow you to ...

Страница 5: ...nsducers Tank and wet well level measurement 5 to 700 feet 05 to 1 full scale accuracy Non fouling diaphragm options for lift station applications 4 20 mA or 0 5 V output AquaSensors Water Quality Instruments The AquaSensors DataStick provides a cost ef fective plug and play analytical measurement sys tem for continuous use in industrial environments DataStick communicates with ControlWave via a p...

Страница 6: ...prove the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user OpenEnterprise SCADA Host T...

Отзывы: