Focus 3 Jumper Setup Worksheet
Refer to the data recorded on the previous page for this worksheet
Refer to your motor nameplate data.
STEP 1
Does your motor have a shunt field winding?
If No go to STEP 5 otherwise go on.
STEP 2
Is your motor field current greater than 1.1A?
If No, go to STEP 3
If Yes
STOP
The Focus 3 Field Supply rectifier will be damaged!!!
Call Tech Support for a solution.
STEP 3
If your motor field voltage is 100 Vdc,
then you must use 120 Vac for Input Power ----- Set JP11 as shown
and Set JP8 to Low
then
go to STEP 7
If you must use 240 Vac -----
Call Tech Support for a solution
otherwise go to STEP 4
STEP 4
If your motor field voltage is 200 Vdc,
then you must use 230 Vac for Input Power ---- Set JP11 as shown
and Set JP8 to Hi
then
go to STEP 7
otherwise
STOP
---- Call Tech Support for a solution
STEP 5
If your motor armature voltage is greater than 110 Vdc,
then you should use 230 Vac for Input Power ---- Set JP11 as shown
and Set JP8 to Hi
then
go to STEP 7
If you must use 120 Vac ----
Call Tech Support for a solution
otherwise go to STEP 7
STEP 6
If your motor armature voltage is less than 110 Vdc,
then you must use 115 Vac for Input Power ----- Set JP11 as shown
and Set JP8 to Lo
then
go to STEP 7
: :
: :