background image

2

Safety Instructions

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,
OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a. Use this unit only in a manner intended by the

manufacturer.  If you have questions, contact the
manufacturer.

b. Before servicing or cleaning unit, switch power off

at service panel and lock service panel
disconnecting means to prevent power from being
switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a warning device, such as a tag, to the
service panel.

WARNING

!

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned

off at the fuse box before wiring, and do not operate
fan without blades.

2. All wiring must be in accordance with the National

Electrical Code “ANSI/NFPA 70-2014” and Local
Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be
grounded as a precaution against possible electrical
shock. Electrical installation should be made or
approved by a licensed electrician.

3. The outlet box and joist must be securely mounted

and capable of reliably supporting at least 50 pounds.
Use only U.L. outlet boxes listed as “Acceptable for
Fan Support of 22.7 kg. (50 lbs.) or less”, and use the

mounting screws provided with the outlet box.
Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if
in doubt.

4. The fan must be mounted with the fan blades at least

7 feet from the floor to prevent accidental contact with
the fan blades.

5. Follow the recommended instructions for the proper

method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed
by a licensed electrician.

WARNING: 

To reduce the risk of electrical shock, this

fan must be installed with an isolating wall control/
switch.

NOTE:

This fan is suitable for use with solid-state speed

controls.

WARNING:

This product is designed to use only those

parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson
Electric Co. Substitution of parts or accessories not
designated for use with this product by Emerson could
result in personal injury or property damage.

WARNING: 

To reduce the risk of personal injury, do not

bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert
foreign objects in between rotating fan blades.

WARNING:

To avoid fire, shock or injury, do not use an

Emerson or any other brand of control not specifically
approved for this fan.

NOTE:

All setscrews must be checked and re-tightened

where necessary before installation.

NOTE:

This fan is suitable for use in wet locations when

installed in a GFCI protected branch circuit.

CAUTION:

To Reduce The Risk Of Injury To Persons,

Install Fan So That The Blade Is At Least 2.1 Meters
(7 Feet) Above The Floor.

1. Read your owner’s manual carefully and keep it for

future reference.

2. Be careful with the fan and blades when cleaning,

painting, or working near the fan. Always turn off the
power to the ceiling fan before servicing.

3. Do not put anything into the fan blades while they are

turning.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record

this data above and keep it in a safe place for future use.

ETL Model No.: CF995

READ AND SAVE THESE INSTRUCTIONS

Table of Contents

Section

Page

Safety Instructions   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions   . . . . . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements    . . . . . . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly    . . . . . . . . . . . . . . . . . . . . . . . . .5-10
4. How to Hang Your Ceiling Fan    . . . . . . . . . . . . . . . . . . .11
5. How to Wire Your Ceiling Fan  . . . . . . . . . . . . . . . . . . . . .12
6. Installation of Light Bulbs   . . . . . . . . . . . . . . . . . . . . . . . .13
7. Transmitter and Receiver Instructions   . . . . . . . . . . . . . .14
8. Programming the Receiver Operating Frequency

& High Speed Conditioning of Fan Control  . . . . . . . . . .15

Section

Page

9.   Remote Control Procedures  . . . . . . . . . . . . . . . . . . . . . .15
10. Instruction to the User   . . . . . . . . . . . . . . . . . . . . . . .16-17
11. Repair Parts   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-17
12. Maintenance   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
13. Accessories  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
14. Trouble Shooting  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Ceiling Fan Limited Warranty   . . . . . . . . . . . . . . . . . . . . . . .19

Содержание CF995BS00

Страница 1: ...UCTIONS LACLEDE 62 Ceiling Fan Owner s Manual CF995BS00 Brushed Steel CF995VNB00 Vintage Steel Model Numbers Net Weight 34 6 Lbs Questions problems missing parts Before returning to the store call Emerson Electric Customer Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com ...

Страница 2: ...an is suitable for use with solid state speed controls WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage WARNING To reduce the risk of ...

Страница 3: ...or missing Call Toll Free for replacement parts 1 800 654 3545 WARNING 1 1 Check to see that you have received the following parts NOTE If you are uncertain of part description refer to exploded view illustration below NOTE Place the parts from the loose parts bags in a small container to keep them from being lost If any parts are missing call 1 800 654 3545 for replacement parts before proceeding...

Страница 4: ...onal injury mount fan to outlet box marked Acceptable for Fan Support of 22 7 kg 50 lbs or less and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure el...

Страница 5: ...DE FLANGE ASSEMBLY MOTOR HUB Figure 2 1 4 20 x 3 8 PAN HEAD SCREW WITH LOCKWASHER Figure 3 3 2 Loosely attach one blade flange assembly to the motor hub by securing the two 1 4 20 x 3 8 pan head screws with captive lockwasher Make sure the screws are loosely tightened for this step Figure 2 Repeat this procedure for other four blade assemblies To reduce the risk of personal injury do not bend the ...

Страница 6: ...ened screw heads into the key hole slots Rotate the lower light fixture clockwise to engage both screws Tighten both screws and reinstall the previously removed screw to secure the fixture Figure 5 NOTE Be careful not to pinch any wires or connectors between the lower light fixture and the lower light adapter plate LOWER LIGHT FIXTURE WHITE CONNECTOR MOTOR WHITE CONNECTOR MOTOR BLACK CONNECTOR LOW...

Страница 7: ...ver Rotate the cover clockwise to engage the screw heads Tighten the screws and reinstall the previously removed screw to secure the cover Figure 6 NOTE Be careful not to pinch any wires or connectors between the lower light cover and the lower light fixture STYROFOAM PARTIALLY ASSEMBLED CEILING FAN Figure 7 3 9 Turn the partially assembled ceiling fan right side up in preparation for final assemb...

Страница 8: ...push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed MOTOR COUPLING DOWNROD MOTOR COUPLER COVER MOTOR COUPLER COVER GROMMET SETSCRE...

Страница 9: ...n the setscrew in the hanger ball A loose setscrew could create fan wobble 3 16 The fan comes with black and white lead wires that are 80 inches long Before installing the fan measure up approximately 6 to 9 inches above top of hanger ball downrod assembly and cut off excess lead wire and strip back insulation 1 2 inch from end of each lead wire It is critical that the pin in the hanger ball is pr...

Страница 10: ...re to keep the rubber pad beneath each clamp to ensure proper clamping 3 19 Carefully secure the upper glass shade by gently tightening the four clamp screws Figure 14 GLASS SHADE CLAMP UPPER GLASS RUBBER PAD CLAMP SCREW Figure 14 10 ETL Model No CF995 3 Ceiling Fan Assembly continued ...

Страница 11: ...ach the hanger bracket to the outlet box using the two screws supplied with the outlet box Figure 16 NOTE Sloped Ceiling Installation The hanger bracket supplied with this fan can accommodate a 35 degree 8 12 pitch ceiling The hanger ball opening must be positioned to face up towards the peak of the ceiling Figure 19 Hanger bracket must seat firmly against outlet box If the outlet box is recessed ...

Страница 12: ...D WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Figure 18 KNURLED KNOBS 2 LOCKWASHERS 2 THREADED STUDS 2 CEILING COVER Figure 19 To avoid possible fire or shock make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover ...

Страница 13: ...16 pan head screw removed previously and tighten all three screws to secure the lower light glass to the lower light assembly Install the finial nut finger tight Figure 22 8 32 x 5 16 PAN HEAD SCREW 3 FINIAL NUT LOWER GLASS SHADE Figure 22 LOWER LIGHT FIXTURE 13W E26 MEDIUM BASE CFL LIGHT BULBS 5 LOWER LIGHT FIXTURE SOCKETS 5 Figure 21 6 2 Lower Light Bulb Installation Install the five supplied 13...

Страница 14: ...n the remote control transmitter to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescent bulbs 3 Reinstall the transmitter battery cover 4 Resto...

Страница 15: ...tions about installation and operation of this ceiling fan 8 Programming the Receiver Operating Frequency High Speed Conditioning of Fan Control 8 1 IMPORTANT Ceiling fan blades MUST be installed before high speed conditioning can begin 1 Within 1 minute of restoring electricity to the ceiling fan push and hold the fan OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan l...

Страница 16: ...he equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This...

Страница 17: ...ve cleaning agents are not required and should be avoided to prevent damage to finish 12 Maintenance Model Numbers Key No Description CF995BS00 CF995VNB00 Hanger Ball Assembly 761655 97 761655 96 Consisting of 1 Hanger Bracket 2 Hanger Ball 3 Downrod 10 Parts Bag Containing 764458 CHRM 764458 BLOX 4 Pin Clevis 1 5 Clip Hairpin 1 6 Threaded Stud 8 32 x 1 1 4 2 7 Lockwasher External Tooth 8 2 8 Knur...

Страница 18: ...xcessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Blades or flanges not tightly fastened to the fan 3 Check all blade and flange screws for tightness 4 Hanger bracket and or ceiling outlet box is not 4 Tighten the hanger bracket screws to the outlet box and or securely fastened secure outlet box WARNING Make sure ma...

Страница 19: ...s limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your receipt or other proof of purchase and have that information readily available when returnin...

Страница 20: ... Service 8 a m 6 p m Eastern Monday Friday 1 800 654 3545 www emersonfans com Retain this manual for future use Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 Part No F40BP74790000 Form No BP7479 Revision 131101 ETL Model No CF995 Printed in China 11 13 ...

Отзывы: