background image

READ AND SAVE THESE INSTRUCTIONS

Model No.

CF955BS 00
CF955ORB 00
CF955WW 00

Part No. F40BP73730000

Form No. BP7373

U.L. Model No.: CF955

Net Weight:  

22.7 

Lbs.

MIDWAY ECO

54” Ceiling Fan

Owner's Manual

LIMITED WARRANTY

What The Warranty Covers:

This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:

As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. Repair and replacement of defective parts on
the light fixture housing or electronics (excluding the lamp) for two years from the date of purchase. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:

Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or
blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.

WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL,
REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center. You will be

responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan
should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:

The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co..
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was
damaged if this product does not work properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

ENERGY STAR

Содержание CF955BS 00

Страница 1: ...ers shown on the product with your request To return the product to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we w...

Страница 2: ...let box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental conta...

Страница 3: ...d of the following size 3 Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted 2 Remove the fan assembly from the protective plastic bag Place the fan assembly into the upper foam pad wi...

Страница 4: ...oth the ceiling cover and the coupler cover are oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the motor leads through the downrod Position the pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew...

Страница 5: ...t box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiri...

Страница 6: ...d the green grounding lead from the hanger bracket to the grounding conductor of supply this may be a bare wire or wire with green colored insulation Securely connect wires with wire connectors supplied Figure 11 NOTE If you are using an Emerson Light Fixture with your fan see Light Fixture Owner s Manual for wiring 2 Securely connect the fan motor white wire to the supply white neutral wire using...

Страница 7: ...OFF up is ON 3 Install the supplied 12V battery into the transmitter with the and terminals are positioned according to the diagram in the battery compartment Replacement batteries for transmitter 12V batteries recommended are Duracell MN21 Eveready A23 and GP23A CEILING COVER THREADED STUD KNURLED KNOB LOCKWASHERS 2 Figure 12 CODE SWITCH BATTERY COVER REMOTE CONTROL TRANSMITTER BATTERY S E T 1 2 ...

Страница 8: ...ace the battery Replacement batteries for transmitter 12V batteries recommended are Duracell MN21 Eveready A23 and GP23A Operation of Your Remote Control FAN SPEED BUTTONS AIR FLOW DIRECTION BUTTON LIGHT LEVEL BUTTON OFF BUTTON 3 4 1 6 2 5 Figure 16 8 Programming the Ceiling Fan Receiver 1 Restore electrical power to the outlet box by turning the electricity on at the main fuse box 2 Flip the wall...

Страница 9: ...ger ball downrod assembly loose 3 Screws securing fan blade flanges to motor are 3 Check to be sure screws which attach the fan blade loose flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the proc...

Страница 10: ...leaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked Acceptable for Fan Support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be re...

Страница 11: ...11 9 4 15 11 6 1 2 3 7 5 14 8 17 16 12 19 10 13 18 3 4 1 6 2 5 Repair Parts U L Model No CF955 ...

Страница 12: ...63743 763743 17 GU 24 Fluorescent 13W Lamp 763747 763747 763747 18 Receiver Motor Control 763742 763742 763742 19 Fuse 1 0A 120W 763744 763744 763744 Owner s Manual BP7373 BP7373 BP7373 Contact your nearest authorized Emerson fan dealer for replacement Fan Light Control Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ...

Отзывы: