background image

5. Reinstall the hanger ball (Figure 5) on the downrod as

follows. Route the two 80” motor leads through the
hanger ball. Position the pin through the two holes in
the downrod and align the hanger ball so the pin is
captured in the groove in the top of the hanger ball.
Pull the hanger ball up tight against the pin. 

Securely

tighten the setscrew in the hanger ball.
A loose setscrew could create fan wobble.

6.Screw in four 40-watt (maximum) candelabra base

lamps in the housing sockets (Figure 6). Grasp the
sockets and pivot them until the lamp bulbs are
even with the outer edge of the housing as shown.
This will provide the optimum lighting effect.

7.The fan comes with black and white leads that are

80” long. Before installing fan, measure up approxi-
mately 6 to 9-inches above top of hanger ball/down-
rod assembly. Cut off excess leads and strip back
insulation 1/2-inch from end of leads.

6

CEILING COVER

DOWNROD

PIN

HANGER
BALL

SETSCREW

Figure 5

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are proper-
ly installed could result in the fan falling.

WARNING

!

TOP ALIGN WITH
OUTER EDGE OF
THE HOUSING

CANDELABRA
BASE LAMP

SOCKET

Figure 6

AT LEAST

7'

CEILING

FLOOR

Figure 7

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician in in doubt.

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.

WARNING

!

WARNING

!

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 7).

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 2

Figure 8

9. Carefully lift the fan and seat the hanger ball/down-

rod assembly on the hanger bracket that was just
attached to the outlet box (Figure 9). Be sure the
groove in the ball is lined up with tab on the hanger
bracket (Figure 8).

WARNING

!

8.Securely attach the hanger bracket to the outlet box

using the two screws supplied with the outlet box.
(Figure 8.)

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

WARNING

!

Содержание CF945AB

Страница 1: ... to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered T...

Страница 2: ...vided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The 4 1 2 downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The 18 downrod furnished with the fan must be used with a 9 foot minimum ceili...

Страница 3: ...k off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to instructions on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experi ence have your fan in...

Страница 4: ...feature If the electrical supply to the receiver is controlled through a wall switch when the switch is turned off the control will remember the light intensities and fan speed When the switch is turned back on the lights and fan will resume operation as they were prior to the switch being turned off Installation of Battery 1 Remove the battery cover by pressing firmly below the arrow and sliding ...

Страница 5: ...h the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Rein...

Страница 6: ...T LEAST 7 CEILING FLOOR Figure 7 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt The outlet box must be securely anchore...

Страница 7: ...IRE CONNECTOR 3 SUPPLY GROUND WIRE GREEN WIRE GROUND FROM HANGERBALL BLACK FAN WIRE BLACK SUPPLY HOT WHITE FAN WIRE Figure 10 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 12 Screw the two threaded studs supplied in...

Страница 8: ...mblies 19 Remove one of the mounting screws from the switch housing plate Figure 14 and loosen the other two screws several turns NOTE If you are installing an Emerson Light Fixture with your fan refer to the Light Fixture Owner s Manual and proceed as follows Remove the center screw from the switch housing and install the light fitter in the threaded hole Connect the blue wire from the light fitt...

Страница 9: ...LY SEE STEP 6 Figure 17 4 Raise the rod support assembly and loosely engage the rod ring with one of the hooks on the rod support assembly Figure 18 Then tighten the setscrew using the 5 64 hex wrench supplied 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 19 ...

Страница 10: ... accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage The use of any other control not specifically approved for this fan could result in fire shock and personal injury 1 Ceiling Fan Light Kits see store or catalog 2 Downro...

Страница 11: ...rned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrews in motor coupling are loose 1 Tighten setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan motor ...

Страница 12: ...3 19 Flange Set of 5 762288 762288 1 762288 2 762288 3 20 Blade Set of 5 761859 24 761859 6 761859 8 761859 17 21 Remote Control Receiver 762291 762291 762291 762291 22 Downrod 18 760239 146 760239 183 760239 40 760239 161 23 Rod Assembly 3 762290 762290 1 762290 2 762290 3 24 Rod Support Assembly 762289 762289 1 762289 2 762289 3 Owner s Manual BP7265 BP7265 BP7265 BP7265 Before discarding packag...

Отзывы: