background image

10

Operation

IMPORTANT

Fan installation must be completed, including the
installation of the fan blades, before testing of the
remote control.

Your remote control has full control of your fan and
lights.

NOTE: Prior to operation of the down light from
the remote control, make sure the switch on the
light is ON.

1. To set the desired fan speed, press the HI, MED,

or LOW button to operate your fan on high,
medium, or low speed.

2. To turn your fan off, press the OFF button.

3. To change the airflow direction of the fan blades,

press the REV button.

4. To turn the downlight on, press and release the D/L

button. The light will turn on at the light intensity
previously selected.

5. To turn the uplight on, press and release the U/L

button. The light will turn on at the light intensity
previously selected.

6. To vary the intensity of the light, hold the U/L or D/L

button down until the desired light intensity is
reached, then release the button.

Accessories

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or acces-
sories not designated for use with this product by
Emerson Company could result in personal injury or
property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

1. Ceiling Fan Light Kits (see store or catalog).

2. Downrod Extension Kits (see store or catalog).

WARNING

!

WARNING

!

REV

MED

OFF

HI

LOW

U

L

D

L

®

STORAGE
BRACKET

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Maintenance

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

!

Installation of

Storage Bracket

A storage bracket is supplied with the remote control
for holding the control unit when not in use. If you
desire to use the bracket, use the two screws
(supplied) and install it on a wall that is away from
excess heat or humidity.

Содержание CF945AB

Страница 1: ... to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered T...

Страница 2: ...vided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The 4 1 2 downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling The 18 downrod furnished with the fan must be used with a 9 foot minimum ceili...

Страница 3: ...k off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembly your ceiling fan refer to instructions on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experi ence have your fan in...

Страница 4: ...feature If the electrical supply to the receiver is controlled through a wall switch when the switch is turned off the control will remember the light intensities and fan speed When the switch is turned back on the lights and fan will resume operation as they were prior to the switch being turned off Installation of Battery 1 Remove the battery cover by pressing firmly below the arrow and sliding ...

Страница 5: ...h the holes in the motor coupling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Rein...

Страница 6: ...T LEAST 7 CEILING FLOOR Figure 7 To reduce the risk of fire electric shock or personal injury mount fan to outlet box marked acceptable for fan support and use screws supplied with outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician in in doubt The outlet box must be securely anchore...

Страница 7: ...IRE CONNECTOR 3 SUPPLY GROUND WIRE GREEN WIRE GROUND FROM HANGERBALL BLACK FAN WIRE BLACK SUPPLY HOT WHITE FAN WIRE Figure 10 Check to see that all connections are tight including ground and that no bare wire is visible at the wire connectors except for the ground wire Do not operate fan until blades are in place Noise and fan damage could result WARNING 12 Screw the two threaded studs supplied in...

Страница 8: ...mblies 19 Remove one of the mounting screws from the switch housing plate Figure 14 and loosen the other two screws several turns NOTE If you are installing an Emerson Light Fixture with your fan refer to the Light Fixture Owner s Manual and proceed as follows Remove the center screw from the switch housing and install the light fitter in the threaded hole Connect the blue wire from the light fitt...

Страница 9: ...LY SEE STEP 6 Figure 17 4 Raise the rod support assembly and loosely engage the rod ring with one of the hooks on the rod support assembly Figure 18 Then tighten the setscrew using the 5 64 hex wrench supplied 5 Engage the other two support rods in the same manner as above Loosen the setscrew and raise the rod support assembly until the support rods are taut and in line with the downrod Figure 19 ...

Страница 10: ... accessories designated specifically for use with this product by Emerson Company Substitution of parts or acces sories not designated for use with this product by Emerson Company could result in personal injury or property damage The use of any other control not specifically approved for this fan could result in fire shock and personal injury 1 Ceiling Fan Light Kits see store or catalog 2 Downro...

Страница 11: ...rned OFF 5 Screws holding blades to flanges 5 Tighten screws securely are loose 3 Fan wobbles 1 Setscrews in motor coupling are loose 1 Tighten setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Screws securing fan blade flanges to 3 Check to be sure screws which attach the fan motor ...

Страница 12: ...3 19 Flange Set of 5 762288 762288 1 762288 2 762288 3 20 Blade Set of 5 761859 24 761859 6 761859 8 761859 17 21 Remote Control Receiver 762291 762291 762291 762291 22 Downrod 18 760239 146 760239 183 760239 40 760239 161 23 Rod Assembly 3 762290 762290 1 762290 2 762290 3 24 Rod Support Assembly 762289 762289 1 762289 2 762289 3 Owner s Manual BP7265 BP7265 BP7265 BP7265 Before discarding packag...

Отзывы: