How to Put Your Ceiling Fan Together

(continued)

BLADE
ASSEMBLY

M6 x 14 CAPTIVE 
SCREWS WITH 
LOCKWASHERS

Figure 8

FAN BLADE

BLADE FLANGE

M5 x 6 WASHER HEAD BLADE SCREW (3)

BLADE WASHER (3)

Figure 7

8.

Turn fan assembly upside down in preparation for
mounting fan blade assemblies.

9.

Mount blade flanges to fan blades using three M5 x
6 washer head blade screws and three blade
washers (Figure 7).

NOTE: Take care not to scratch fan housing when
installing blades.

NOTE: Remove and discard the four shipping
spacers and screws from the motor hub.

10.

Loosely attach one blade assembly to the motor
hub using two M6 x 14 captive screws with
lockwashers. Make sure the screws are NOT
tightened. (Figure 8.) Repeat this procedure for
other four blade assemblies.

11.

The blade flanges have an interlocking feature
that must be fully engaged before tightening the
screw. Make sure all the flanges are properly
engaged and then tighten the flange screws. If
one of the flanges does not seat properly on the
motor hub, loosen the adjacent flange screws, re-
engage and reseat the flanges, then tighten the
screws again.

12.

You have now completed the assembly of your
new ceiling fan. You can now proceed with
hanging and wiring your fan.

To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.

WARNING

!

U.L. Model No.: CF755

Electrical Requirements

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.

To avoid fire or shock, follow all wiring instructions
carefully. Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

WARNING

!

WARNING

!

To reduce the risk of fire, electrical shock, or
personal injury, mount fan to outlet box marked
“Acceptable for Fan Support”, and use screws
supplied with outlet box. Most outlet boxes
commonly used for support of light fixtures are not
acceptable for fan support and may need to be
replaced. Consult a qualified electrician if
in doubt.

WARNING

!

Содержание CF755AB06

Страница 1: ...AB06 CF755BS06 CF755ORB06 CF755VNB06 CF755WW06 Part No F40BP73170002 Form No BP7317 2 U L Model No CF755 READ AND SAVE THESE INSTRUCTIONS Ceiling Fan Owner s Manual Model Numbers DESIGNER Net Weight 18 0 Lbs ...

Страница 2: ... use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7...

Страница 3: ...se parts bag containing 1 Sixteen M5 x 6 washer head blade screws 2 Sixteen blade washers 3 One M6 x 14 captive screw with lockwasher 4 One wood pendant 5 One coupling 6 Three wire connectors 7 Two threaded studs 8 Two knurled knobs 9 Two lockwashers 10 One clevis pin 11 One hairpin clip Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is desig...

Страница 4: ...pling and the holes in the downrod Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin The hairpin clip must be properly installed to prevent the clevis pin from working loose Pull on the downrod to make sure the clevis pin is properly installed Reinstall the upper setscrew in ...

Страница 5: ... hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 6 Engage the connector of the switch housing assembly with the motor connector Figure 5 The two connectors are keyed and color coded and must be mated correctly color to color before they can be engaged Make sure the connector latch closes properly 7 Remove the three switch housing mounting scre...

Страница 6: ...f personal injury do not bend the blade flange when installing the blade flanges balancing the blades or cleaning the fan Do not insert foreign objects in between rotating fan blades WARNING U L Model No CF755 Electrical Requirements If your fan is to replace an existing ceiling light fixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceil...

Страница 7: ...at firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard 2 Carefully lift the fan and seat the hanger ball downrod assembly onto the hanger bracket that was just atta...

Страница 8: ...red to be turned on and off from the fan switch 8 How to Wire Your Ceiling Fan Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock NOTE CEILING COV...

Страница 9: ...ly heavily on the proper installation and use of the ceiling fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal airflow Consult y...

Страница 10: ...shock and personal injury 1 Ceiling Fan Light Kits see store or catalog 2 Ceiling Fan Light Controls see store or catalog 3 Downrod Extension Kits see store or catalog WARNING WARNING Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching...

Страница 11: ...rior wall of the switch housing WARNING Make sure main power is turned OFF 5 Motor noise caused by solid state 5 Some fan motors are sensitive to signals from variable speed control Solid State variable speed controls If Solid State Control is used and motor noise results choose an alternative control method 6 Screws holding blades to flanges 6 Tighten screws securely are loose 3 Fan wobbles 1 Set...

Страница 12: ...12 U L Model No CF755 Repair Parts 14 7 6 13 9 19 20 5 4 15 1 2 3 17 16 12 10 18 11 8 ...

Страница 13: ...eiling 761620 3 761620 25 761620 33 761620 VNB 761620 11 Wiring Harness 762993 1 762993 2 762993 1 762993 1 762993 3 12 Switch Housing 763151 AB 763151 BS 763151 ORB 763151 VNB 763151 WW 13 Blade Set of 5 761859 30 761859 30 761859 29 761859 30 761859 3 14 Flange Set of 5 763154 AB 763154 BS 763154 ORB 763154 VNB 763154 WW 20 Coupling Cover 762463 4 762463 8 762463 16 762463 VNB 762463 15 Owner s ...

Страница 14: ...14 U L Model No CF755 Notes ...

Страница 15: ...15 U L Model No CF755 Notes ...

Страница 16: ...d have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your rece...

Отзывы: