What The Warranty Covers:

This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.

What The Period Of Coverage Is:

As it applies to the motor, this warranty will last for a lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one
year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE
WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.

What Will Emerson Electric Co. Do To Correct Problems:

Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Electric Co. will refund the actual purchase
price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and
shipping of the product to Emerson Electric Co.

How Can You Get Service:

YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.

• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson

Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.

• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.

You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.

What Is Not Covered:

The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:

• Repairs by persons not authorized by Emerson Electric Co.,

• Use of parts or accessories not authorized by Emerson Electric Co.,

• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or

• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.

Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:

• The original purchaser or user ceases to own the product, or

• The fan is moved from its original point of installation.

This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co.

REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON ELECTRIC CO. IS NOT
RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to
such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which
was damaged if this product does not work properly.

How State Law Relates To The Warranty:

Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This
warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

IMPORTANT CARE INSTRUCTIONS

for your Ceiling Fan

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Maintenance

Accessories

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

1.

Ceiling Fan/Light Controls (see store or catalog).

2.

Downrod Extension Kits (see store or catalog).

WARNING

!

WARNING

!

WARNING

!

U.L. Model No.: 42-ANT/52-ANT

Содержание CF710AB02

Страница 1: ...S PRO SERIES II Ceiling Fan Owner s Manual Net Weight 19 8 Lbs Net Weight 15 0 Lbs 50 PRO SERIES II Model No CF711AB02 CF711ORS02 CF711AW02 CF711PB02 CF711BS02 CF711WB02 CF711CK02 CF711WW02 CF711ORB02 42 PRO SERIES II Model No CF710AB02 CF710AW02 CF710BS02 CF710ORB02 CF710PB02 CF710WW02 CF711 shown ...

Страница 2: ... Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades ...

Страница 3: ...h step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted Before assembling your ceiling fan refer to section on proper method of wiring your fan page 6 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or u...

Страница 4: ...d to be installed either in the standard manner or in the close to the ceiling manner Using the standard method the hanger ball downrod assembly will suspend the fan several inches below the ceiling cover Using the close to the ceiling method the ceiling cover installs directly on the fan motor housing thus mounting the fan 3 1 2 inches closer to the ceiling than the standard method In no case sho...

Страница 5: ...nd or outlet box are not securely attached the fan could wobble or fall WARNING Hanging The Ceiling Fan Standard Method Using Hanger Ball Downrod 1 Carefully lift the fan assembly and seat the hanger ball in the hanger bracket Figure 7 The tab on the hanger bracket must seat in the groove in the hanger ball NOTE The hanger bracket must be mounted flush with the ceiling in order for the ceiling cov...

Страница 6: ...g off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local Codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING Hanging The Ceiling Fan Close to the Ceiling Method with Ceiling Cover Installed on the Motor...

Страница 7: ... blade Figure 11 2 Securely connect the fan motor white wire to the supply white neutral wire using wire connector supplied Figure 9 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 9 After connections have been made turn leads upward and carefully push leads into the outlet box with the white and green leads on one side of t...

Страница 8: ...P SQUEEZE RETAINING CLIPS TOGETHER AND SLIDE ON GLASS SHADE GLASS SHADE 13W E26 MEDIUM BASE BULB CFL 3 or 4 Figure 13 2 Mount one blade assembly to the motor hub by mating the alignment post Figure 11 of the flange with one of the alignment slots in the motor hub Figure 12 Then tighten the two captive screws in the flange to secure the flange to the motor hub Repeat this procedure for the other fo...

Страница 9: ...flanges to motor hub 2 Check to make sure the screws which attach the fan are loose flanges to the motor hub are tight 3 Wire connectors inside switch housing rattling 3 Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing WARNING Make sure main power is turned off 4 Motor noise caused by solid state variable 4 ...

Страница 10: ...of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your ceiling fan while in your possession or Unreasonable use misuse abuse including failing to do reasonable and necessary maintenance and normal wear and tear Additionally this warranty and any implied warranty of merchantability or fitness for a particular purpose are voide...

Страница 11: ...rding packaging material be certain all parts have been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION NAME OF ITEM MODEL NUMBER For repair parts phone 1 800 654 3545 U L Model No 42 ANT 52 ANT ...

Страница 12: ...asher Head 16 16 Flange Screw Phillips Round Head 1 17 Rubber Gasket Owner s Manual BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 BP7258 8 Repair Parts Listing Form No BP7258 8 Part No F40BP72580008 Printed in China 06 10 Air Comfort Products DIVISION OF Emerson Electric Co 8100 W Florissant St Louis MO 63136 42 PRO SERIES II Model Numbers Key No Description CF710AB02 CF7...