manualshive.com logo in svg
background image

5

How to Put Your Ceiling Fan Together

(continued)

FAN MOTOR 
ASSEMBLY

CEILING 
COVER

DOWNROD

RUBBER GROMMET

COUPLER COVER

Figure 3

4.

Make sure the rubber grommet is properly installed
onto the coupling cover then slide the coupler
cover onto the downrod until it rests on top of the
motor housing. Place the ceiling cover over
the downrod. Be sure both the ceiling cover and
the coupler cover are oriented correctly (Figure 3).

5.

Route the motor leads through the hanger ball.
Reinstall the hanger ball (Figure 4) on the
downrod. Reinstall the pin through the two holes in
the downrod. Slide the ball upwards and align the
ball so the  pin is captured in the groove in the top
of the hanger ball. Pull the hanger ball up tight
against the pin and securely tighten the setscrew in
the hanger ball. A loose setscrew could create fan
wobble.

6.

The fan comes with black and white leads that are
80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

7.

Position one fan blade on the flange assembly of
the motor assembly and secure by installing four
#10-24 x .375” flat head screws and four #10 x .50”
flat washers (supplied) (Figure 5).

8.

Install the remaining four fan blades using the
same procedure.

NOTE: Take care not to scratch fan housing when
installing blades.

9.

You have now completed the initial assembly of your
new ceiling fan. You can now proceed with hanging
and wiring your fan.

ETL Model No.: CF550

#10-24 x .375" FLAT HEAD 
SCREWS (4 per blade)

#10 x .50" FLAT 
WASHERS
(4 per blade)

BLADE FLANGE

FAN BLADE

Figure 5

To reduce the risk of personal injury, do not bend the
blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.

WARNING

!

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

CEILING 
COVER

DOWNROD

HANGER BALL

PIN

SETSCREW

Figure 4

Содержание CF550BS00

Страница 1: ...SE INSTRUCTIONS 54 Ceiling Fan Owner s Manual CF550BS00 CF550ORB00 Model Number LUXE ECO Net Weight 20 9 Lbs DATE CODE The date code of this fan may be found on the box stamped in ink on a white label You should record this data above and keep it in a safe place for future use ...

Страница 2: ...m the floor to prevent accidental contact with the fan blades 6 Follow the recommended instructions for the proper method of wiring your ceiling fan If you do not know enough about electrical wiring have your fan installed by a licensed electrician NOTE All setscrews must be checked and re tightened where necessary before installation NOTE This fan is suitable for use with solid state speed contro...

Страница 3: ... local retailer or catalog outlet for replacement before proceeding Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this ...

Страница 4: ...WNROD HAIRPIN CLIP DOWNROD HAIRPIN CLIP MOTOR COUPLING CLEVIS PIN SETSCREW 2 Figure 2 PIN HANGER BALL SETSCREW DOWNROD Figure 1 1 Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod Figure 3 Remove the pin from the downrod then remove the hanger ball Retain the pin and hanger ball for reinstallation in Step 5 2 Loosen setscrews in motor ...

Страница 5: ...ove top of hanger ball downrod assembly Cut off excess leads and strip back insulation 1 2 inch from end of leads 7 Position one fan blade on the flange assembly of the motor assembly and secure by installing four 10 24 x 375 flat head screws and four 10 x 50 flat washers supplied Figure 5 8 Install the remaining four fan blades using the same procedure NOTE Take care not to scratch fan housing wh...

Страница 6: ...t must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard 2 Carefully lift the fan and seat the hanger ball downrod assembly onto the hanger bracket that was ...

Страница 7: ...he ceiling fan must be properly grounded as a precaution against possible electrical shock NOTE CEILING COVER OMITTED FOR CLARITY GROUND WIRE LISTED WIRE CONNECTOR 3 GREEN WIRE GROUND FROM HANGER BRACKET GREEN WIRE GROUND FROM HANGER BALL WHITE SUPPLY NEUTRAL WHITE FAN WIRE BLACK SUPPLY HOT BLACK FAN WIRE Check to see that all connections are tight including ground and that no bare wire is visible...

Страница 8: ... the three raised studs in the light kit assembly Then turn the glass shade clockwise until it stops and is secure Figure 14 NOTE Periodically check that the glass bowl is seated fully clockwise in the light kit assembly 9 Installation of your ceiling fan is now complete Proceed with installation of the wall control Lower Light Kit Assembly REMOVE RETAIN ONE SCREW FROM MOTOR HOUSING LIGHT KIT WHIT...

Страница 9: ...e wall control to your choice of ON up or down positions Use a ball point pen or small screwdriver and slide the levers firmly up or down 2 The sixth switch marked ON and I is for dimming control of lights Set switch to ON to allow for dimming of the lights Set switch to I for no dimming of the lights such as for fluorescent bulbs WALL CONTROL CODE SWITCHES ON 1 2 3 4 5 I CODE SWITCHES WALL CONTRO...

Страница 10: ...stallation is completed Figure 17 FAN LIGHT WALL CONTROL WALL BOX BLACK BLK HOT SWITCH COVER DECORATIVE WALL PLATE SCREWS 2 NEUTRAL WIRES TO 120VAC SOURCE TO LOAD G R OUND Figure 17 3 WAY INSTALLATION One fan controlled by two different wall controls See Figures 18 and 19 1 Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install the ceiling...

Страница 11: ...ires are visible at the wire connectors WARNING STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLACK SW605 FAN LIGHT WALL CONTROL TRAVELER WIRE BLK BLK LOAD BLACK GROUND NEUTRAL RECEIVER LOCATED ON TOP OF THE CEILING FAN EMERSON EMERSON HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 18 Figure 19 HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL FAN LIGHT WALL CONTROL...

Страница 12: ...OFF button for 3 to 5 seconds to set the code in the receiver The ceiling fan lights if installed will blink to indicate the transmitted has been paired with the receiver IMPORTANT Immediately after successful pairing the ceiling fan will automatically begin high speed conditioning of the motor During conditioning the electronic motor control software is calculating speeds for the 2nd through 5th ...

Страница 13: ...n motor coupling is loose 1 Tighten both setscrews securely in the motor excessively coupling 2 Setscrew in hanger ball downrod 2 Tighten the setscrew in the hanger ball assembly is loose downrod assembly 3 Fan blade flanges are loose or not properly 3 Check to be sure the fan blade flanges are seated properly seated into the blade holders firmly and uniformly into the blade holders If blades are ...

Страница 14: ...14 ETL Model No CF550 Repair Parts 1 7 3 2 13 14 6 10 11 18 12 15 16 17 19 20 9 8 5 4 ...

Страница 15: ...ng Kit 1 13 Cover Ceiling 1 764240 BS 764240 ORB 14 Coupler Cover 1 762463 BS 762463 ORB 15 Light Kit Assembly 1 764250 BS 764250 ORB 16 Light Kit Cover Plate 1 764256 BS 764256 ORB 17 Light Kit Glass Shade 1 764253 OM 764253 OM 18 Blades set of 5 764248 DM 764248 WA 19 Wall Control Transmitter 6 Speed SW605 SW605 20 Control Receiver 764087 1 764087 1 Owner s Manual BP7453 1 BP7453 1 Before discar...

Страница 16: ...d have proof of your purchase of the Emerson Ceiling Fan to obtain your remedy under this limited warranty You can return your Emerson Ceiling Fan to your place of purchase or you can call Emerson Customer Service at 1 800 237 6511 to obtain a return authorization and service identification tag In order for us to confirm that your Emerson Ceiling Fan is still under warranty please retain your rece...

Отзывы: