8. Wall Control Installation
(Continued)
3-WAY WIRING DIAGRAM:
NEW CONSTRUCTION
NOTE: Retrofit 3-way installations are likely to
include two traveler wires between the two wall
boxes. In new construction, only one traveler wire Is
required (See Figure 36).
8.14
Screw the Wall Control into Wall Box using the supplied
Screws. Leave the Wall Control in “OFF” mode until
Fan installation is completed.
8.15
The Wall Control is supplied with a White, Ivory, and
Almond color Switch Covers. Choose the finish that
best suits your needs and snap the Cover onto the Wall
Control (Figure 36).
8.16
Next, install the other Wall Control (sold separately) into
the Wall Box containing the “LOAD” Wire. Connect the
Black Wire of the Wall Control to the Traveler Wire(s)
already connected to the Black Wire (in the other wall
box). Secure with Wire Connectors, supplied.
8.17
Connect one Black Wire of the Wall Control to the
“LOAD” (Black) Wire and secure with Wire Connector,
supplied.
8.18
Connect one Black Wire of the Wall Control to both
remaining Traveler Wires in the Wall Box and secure
with Wire Connector, supplied.
Figure 36
Check to see that all connections are tight and that no
bare wires are visible at the wire connectors.
WARNING
!
STANDARD WIRING FOR EXISTING
3-WAY CONTROLS
3-WAY WIRING DIAGRAM: RETROFIT