How to Hang Your Ceiling Fan

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 11).

AT LEAST

7'

CEILING

FLOOR

Figure 11

WARNING

!

The outlet box and joist must be securely mounted and
capable of supporting at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support”.

WARNING

!

To reduce the risk of fire, electrical shock, or personal
injury, mount fan to outlet box marked “Acceptable for
Fan Support”, and use screws supplied with outlet box.
Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may
need to be replaced. Consult a qualified electrician if in
doubt.

WARNING

!

U.L. Model No.: CF542

NOTE: CEILING COVER
OMITTED FOR CLARITY.

OUTLET
BOX

HANGER
BRACKET

HANGER BALL/
DOWNROD ASSEMBLY

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

Figure 13

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

WARNING

!

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

2.

Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 13). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 12).

WARNING

!

WARNING

!

1.

Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box.
(Figure 12.)

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

HANGER
BRACKET

TAB

OUTLET
BOX

Figure 2

Figure 12

Содержание CARRERA VERANDA CF542AW00

Страница 1: ...30000 Form No BP7403 U L Model No CF542 READ AND SAVE THESE INSTRUCTIONS 42 Ceiling Fan Wet Location Owner s Manual CF542AW00 Summer White CF542ORB00 Oil Rubbed Bronze Model Numbers CARRERA VERANDA Net Weight 17 6 Lbs ...

Страница 2: ...ost outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with...

Страница 3: ...ore assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories desig...

Страница 4: ...ixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To avoid fire or shock follow all wiring instructions carefully Any electrical work not described...

Страница 5: ...e so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover 7 Turn the bracket switch housing assembly clockwise and tighten both screws Figure 4 Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly M4 x 12mm FLAT HEAD SCREW 3 SWITCH HOUSING ASSEMBLY Figure 6 To avoid possible fire or shock do not...

Страница 6: ...hanger ball Figure 10 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Remove ...

Страница 7: ...OD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 13 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan coul...

Страница 8: ...g wire connector supplied Figure 14 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 14 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue unground...

Страница 9: ...ing fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance Accessories Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock This product ...

Страница 10: ...d properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet 5 Tighten the hanger bracket screws to the outlet box is not securely fastened box and or secure out...

Страница 11: ...ant 16 Balancing Kit 1 17 Canopy Ceiling 1 763921 AW 763921 ORB 18 Wiring Harness 1 763981 5 763981 3 19 Switch Housing 1 763919 AW 763919 ORB 20 Coupling Cover 1 763922 AW 763922 ORB 21 Flange set of 5 763930 AW 763930 ORB 22 Blade set of 5 763932 AW 763932 ORB 23 Switch Housing Adapter Cover Assembly 763915 AW 763915 ORB Owner s Manual BP7403 BP7403 11 14 13 17 20 21 6 5 9 22 23 10 11 15 18 19 1...

Страница 12: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Отзывы: