background image

CEILING
COVER

HANGER BALL

PIN

SETSCREW

Figure 10

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

!

16.

The fan comes with blue, black and white leads
that are 80” long. Before installing fan, measure
up approximately 6 to 9-inches above top of
hanger ball/downrod assembly. Cut off excess
leads and strip back insulation 1/2-inch from end
of leads.

17.

You have now completed the assembly of your
new ceiling fan. You can now proceed with
hanging and wiring your fan.

14.

Make sure the grommet is properly installed in
the coupling cover, then slide the coupling cover
on the downrod until it rests on the motor
housing. Place the ceiling cover over the
downrod. Be sure that the ceiling cover and the
coupling cover are both oriented correctly
(Figure 9).

6

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.

WARNING

!

DOWNROD

CEILING
COVER

COUPLING COVER

Figure 8

DOWNROD

CEILING
COVER

COUPLING COVER

Figure 9

NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.

15.

Reinstall the hanger ball (Figure 10) on the
downrod as follows. Route the three 80” motor
leads through the hanger ball. Position the pin
through the two holes in the downrod and align
the hanger ball so the pin is captured in the
groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.

12.

Remove the hanger ball by loosening the
setscrew in the hanger ball until the ball falls
freely down the downrod (Figure 7). Remove the
pin from the downrod, then remove the hanger
ball. Retain the pin and hanger ball for
reinstallation in Step 15.

13.

Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Remove the upper setscrew from the
motor coupling. Align the clevis pin holes in the
downrod with the holes in the motor coupling.
Install the clevis pin and secure with the hairpin
clip (Figure 8). The clevis pin must go through the
holes in the motor coupling and the holes in the
downrod. Be sure to push the straight leg of the
hairpin clip through the hole near the end of the
clevis pin until the curved portion of the hairpin
clip snaps around the clevis pin. The hairpin clip
must be properly installed to prevent the clevis pin
from working loose. Pull on the downrod to make
sure the clevis pin is properly installed. Reinstall
the upper setscrew in the motor coupling. Check
that the lower setscrew is tightened securely
(Figure 8).

PIN

SETSCREW

HANGER
BALL

DOWNROD

Figure 7

U.L. Model No.: CF542

Содержание CARRERA VERANDA CF542AW00

Страница 1: ...30000 Form No BP7403 U L Model No CF542 READ AND SAVE THESE INSTRUCTIONS 42 Ceiling Fan Wet Location Owner s Manual CF542AW00 Summer White CF542ORB00 Oil Rubbed Bronze Model Numbers CARRERA VERANDA Net Weight 17 6 Lbs ...

Страница 2: ...ost outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with...

Страница 3: ...ore assembly your ceiling fan refer to section on proper method of wiring your fan page 8 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician Do not install or use fan if any part is damaged or missing Call Toll Free 1 800 654 3545 This product is designed to use only those parts supplied with this product and or any accessories desig...

Страница 4: ...ixture turn electricity off at the main fuse box at this time and remove the existing light fixture Your new ceiling fan will require a grounded electrical supply line of 120 volts AC 60 Hz 15 amp circuit The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds To avoid fire or shock follow all wiring instructions carefully Any electrical work not described...

Страница 5: ...e so that the two screws mate with the two keyhole slots in the bracket switch housing assembly with rubber cover 7 Turn the bracket switch housing assembly clockwise and tighten both screws Figure 4 Reinstall the other serrated head screw in the remaining hole in the bracket switch housing assembly M4 x 12mm FLAT HEAD SCREW 3 SWITCH HOUSING ASSEMBLY Figure 6 To avoid possible fire or shock do not...

Страница 6: ...hanger ball Figure 10 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball A loose setscrew could create fan wobble 12 Remove ...

Страница 7: ...OD ASSEMBLY NOTE CEILING COVER SUPPLY WIRES AND FAN WIRES OMITTED FOR CLARITY Figure 13 To avoid possible fire or shock do not pinch wires between the hanger ball downrod assembly and hanger bracket WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan coul...

Страница 8: ...g wire connector supplied Figure 14 Securely connect the fan motor black wire and blue wire to the supply black hot wire using wire connector supplied Figure 14 After connections have been made turn leads upward and carefully push leads into the outlet box with the green equipment grounding conductor and white grounded neutral conductor on one side of the outlet box and the black and blue unground...

Страница 9: ...ing fan is the only maintenance that is needed When cleaning use only a soft brush or lint free cloth to avoid scratching the finish Abrasive cleaning agents are not required and should be avoided to prevent damage to finish Maintenance Accessories Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock This product ...

Страница 10: ...d properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet 5 Tighten the hanger bracket screws to the outlet box is not securely fastened box and or secure out...

Страница 11: ...ant 16 Balancing Kit 1 17 Canopy Ceiling 1 763921 AW 763921 ORB 18 Wiring Harness 1 763981 5 763981 3 19 Switch Housing 1 763919 AW 763919 ORB 20 Coupling Cover 1 763922 AW 763922 ORB 21 Flange set of 5 763930 AW 763930 ORB 22 Blade set of 5 763932 AW 763932 ORB 23 Switch Housing Adapter Cover Assembly 763915 AW 763915 ORB Owner s Manual BP7403 BP7403 11 14 13 17 20 21 6 5 9 22 23 10 11 15 18 19 1...

Страница 12: ...orized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass gl...

Отзывы: